In this section:
Use the SIP JJ9030Interworking Profile window to configure SIP JJ9030 Interworking profiles which contain parameters needed for SIP JJ9030 Interworking. For information on other related profiles for SIP-ISUP and interworking between different SIP variants, refer to Support for SIP-ISUP.
On the SBC main screen, navigate to All → Profiles → Signaling → SIP JJ9030Interworking Profile.
The SIP JJ9030Interworking Profile window opens:
Figure 1: SIP JJ9030Interworking Profile Window
To Create a SIP JJ9030 Interworking Profile
To create a new SIP JJ9030 Interworking Profile:
Click New SIP JJ9030 Interworking Profile. The Create New SIP JJ9030Interworking Profile window opens.
Use the following table to configure the parameters and then click Save.
Table 1: SIP JJ9030 Interworking Profile Parameters
Field | Length/Range | Description |
---|---|---|
Name | 1-23 characters | The name of this SIP JJ-90.30 Interworking Profile. NOTE: You can configure a maximum of 32 SIP JJ9030 Interworking Profiles. |
SIP Flavor | N/A | The type of SIP parameters and procedures used for this interworking profile.
|
Orig Ioi | 1-128 characters | The name of the Originating Inter Operator Identifier. |
Term Ioi | 1-128 characters | The name of the Terminating Inter Operator Identifier. |
Originating Carrier Code | 4 digits (0-9 ) | The Originating Carrier Code, consisting of 4 digits (0-9). NOTE: This parameter is mandatory when the parameter SIP Flavor is set to JJ9030. |
Terminating Carrier Code | 4 digits (0-9 ) | The Originating Carrier Code, consisting of 4 digits (0-9). |
Charge Area Information | 5 digits (0-9 ) | The Charge Area Information, consisting of 5 digits (0-9). |
Add User Equal Phonefor Div Hi Interworking | N/A | Enable this parameter to add "user=phone" and the "mp" parameter for Diversion History Info Interworking.
|
Set Hi Presentation Restricted | N/A | Set Presentation Indicator as "restricted" for History Info Interworking.
|
BCI Charge Indicator | N/A | The Backwards Call Indicators Charge Indicator.
NOTE: This parameter is mandatory when the parameter SIP Flavor is set to SIP-ttc-charging-params. |
BCI Called Party Category | N/A | The Backwards Call Indicators Called Party Category.
NOTE: This parameter is mandatory when the parameter SIP Flavor is set to SIP-ttc-charging-params. |
BCI Terminating ISDN Access | N/A | The Backwards Call Indicators Terminating ISDN Access Indicator.
NOTE: This parameter is mandatory when the parameter SIP Flavor is set to SIP-ttc-charging-params. |
Transit Pcv | N/A | When enabled, the SBC transits icid-value, orig-ioi and term-ioi of P-Charging-Vector transparently in JJ90.30 to JJ90.30 calls, using the current trunk group.
Note:
|
Transit Icid In Invite | N/A | When enabled, the SBC transits the icid-value in P-Charging-Vector transparently in the INVITE sent on the current trunk for JJ90.30 to JJ90.30 calls.
Note:
|
To edit a SIP JJ9030 Interworking Profile:
To copy a SIP JJ9030 Interworking Profile:
To delete a SIP JJ9030 Interworking Profile:
If a SIP JJ9030 Interworking Profile is associated with a SIP trunk group, remove it from the trunk group before deleting it.