Resources | profiles | signaling | isupSignalingProfile | sendAPPinAPMforCBWF

sendAPPinAPMforCBWF

Controls whether to send CBWF Information in APP parameter(ACI=126) in a new APM message or to send the APP in the next backward messages like ACM,ANM etc.

NameValue
Type
NamesendAPPinAPMforCBWF
PresenceO
DefaultunSupported
Base Typeenumeration
constraintsunSupported supported