You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 5 Current »

Note

Not applicable to the SBC Software Edition (SWe).


Type: MAJOR
                                                                                                                                                                                                                                                                                                                  

Object ID1.3.6.1.4.1.2879.2.8.1.4.1.1.0.1

Description

This alarm indicates that a power supply of the server failed.

Repetition

None

Event Codes

sonusConnexIpSystemAdminName
sonusConnexIpSystemServerName
sonusConnexIpSystemPowerSupplyId

Instance Fields

None

Action

Replace the power supply or source of power.

Refer to the respective hardware installation guide for power supply replacement procedures.

Impact

The server is running with unprotected power supply. There is a loss of power supply redundancy. If both the power supplies fail, the server will be down.

Clearing

Automatic, sonusConnexIpSystemCEPowerSupplyNormalNotification