Resources | oam | alarms | ethernetCrcErrAlarm

ethernetCrcErrAlarm

This table contains Ethernet CRC error alarm configuration.

Configuration

ParameterPresenceTypeDefaultDescription
setThresholdOuint320 The rate threshold which will set an alarm. Setting it to 0 will disable the alarm.
clearThresholdOuint32100 The rate threshold which will clear an alarm.
REST API: GET Example

curl -kisu 'admin:secret' -X GET https://{SBX-SERVER}/api/config/oam/alarms/ethernetCrcErrAlarm