You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 3 Current »

Type: MAJOR

Object ID1.3.6.1.4.1.2879.2.10.1.1.4.0.27

Description

This trap indicates that the JSRC Server is down.

Repetition

None

Event Codes

sonusJSrcServerName - Specifies the name of the server in the jsrcServer remoteServer table.

Instance Fields

None

Action

If system jsrcServer and the srcReconnectPollTimeout is set to 0, the server must be manually disabled and re-enabled to bring the server back in service, else, an automatic reconnect occurs. In either case, check the connectivity to, and the health of, fields of the remote server.

Impact

If only one remote Server is configured, calls requiring source reservations fails, else, call capacity may be affected.

Clearing

Automatic, sonusJsrcServerStateDownNotification

  • No labels