Revert Software Version window provides the options to revert from current SBC software version to the previous version.

On SBC main screen, go to  Administration > System Administration > Revert Software Version. The Revert Software Version window is displayed.

Initial Revert Software Version Screen

This window is divided into two panes :

Installed Software Versions

This pane lists the software versions installed on each partition of the SBC. This information displayed in this pane is based on whether the SBC is standalone or part of an HA pair.

The following parameters are displayed:

Installed Software Versions Parameters

Parameter NameDescription
System /Partition

Specifies the server name followed by the label Version 1 or Version 2.

Version 2 - This is the latest boot version.

Version 1 - This is the older version which you can revert to.

Installed Software VersionSpecifies the SBC installed software version. 
Current Boot VersionSpecifies whether this partition is the current boot version of the SBC. If this System/Partition is the current boot version, then it
indicated with the (tick) icon.

In the following example, the SBC is standalone and Version 2 is the current boot version.

Installed Software Versions Screen

Revert Software

This pane provides the details on reverting the SBC software. If the software version for the SBC is supported for reverting, then a list of the specific server name(s) is displayed in the Revert Software pane.

Initial Revert Software Screen

The following parameters are displayed :

Revert Software Parameter Information

Parameter NameDescription
Revert the software boot versionThis specifies the name of the servers used for reverting.
VersionThis specifies the revert version of the SBC application.
Last usedThis specifies when the SBC software was last used.

To Revert Software

  1. Click to start the revert process.

    Revert Software

     

    A confirmation Change Boot Version window is displayed.

    Change Boot Version Window

  2. Click Ok to continue. The revert operation takes around 15 to 20 minutes to complete.
    After successful completion, a Finished status along with log is displayed in the Revert Software pane. For more information on reverting SBC application, refer to Reverting SBC Application.

    In the following example, SBC is part of an HA pair.

    Successful Revert Software Screen