You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 14 Next »

It is important to select the correct firmware file for the existing platform type. The upgrade fails if the platform type mismatches with the selected firmware upgrade file. For example: For SBC 7000 Series platform, the firmware upgrade file should be firmware-7x00-V0x.xx.00-R000.img file.

The following details helps to choose the correct firmware file for an upgrade:

Platform TypeFirmware file
SBC 5000 Series
(5100, 5110, 5200, 5210)

Upgrade from 2.x to 3.x version:

  • bmc5X00_v3.xx.00-R000.rom
  • bmc5X00_v3.xx.00-R000.rom.md5sum

Upgrade from 3.x to 3.y version:

  • firmware-5XX0-V03.yy.00-R000.img
  • firmware-5XX0-V03.yy.00-R000.img.md5

 

SBC 5400

Upgrade from any version to latest version:

  • firmware-5400-V03.xx.00-R000.img
  • firmware-5400-V03.xx.00-R000.img.md5
SBC 7000 Series

Upgrade from any version to latest version:

  • firmware-7x00-V03.xx.00-R000.img
  • firmware-7x00-V03.xx.00-R000.img.md5

Upgrade BMC Firmware for SBC 5400 and SBC 7000 Series

The SBC 5400 and the SBC 7000 Series BMC firmware is upgraded using the standard upgrade method (using the ".rom" file). The standard upgrade method allows you to directly upgrade from any version to the latest BMC version.

Note

This method is applicable only to SBC 5400. 

Upgrade Paths for SBC 5000 Series (5100, 5110, 5200, 5210)

The two BMC Firmware upgrade paths are listed below. Identify the file type to use for an upgrade:

  • BMC upgrade from 2.x to 3.x: Use the ".rom" file. 
    For example: To upgrade from BMC 02.16.00 to 03.00.00, use "bmc5X00_v3.0.0-R0.rom" file.

    Note

    The firmware upgrade to 3.x can only be done from version 02.16.00 or later. If the existing BMC version is older than 02.16.00, upgrade it to 02.16.00 using the standard method first and then perform an upgrade to 3.x version using  a ".rom" file. 

  • BMC upgrade from 3.x to 3.y: Use the "Disc Image File". 
    For example: To upgrade from BMC 03.00.00 to 03.11.00, use "firmware-5XX0-V03.11.00-R000.img" file.

Upgrade BMC Firmware from 2.x Version for SBC 5000 Series (5100, 5110, 5200, 5210)

The following procedure describes how to upgrade the BMC firmware from 2.x to 3.x versions (02.16.00 to 03.00.00) using the ".rom" file.

Note

Download the required BMC firmware version from Salesforce prior to continuing. Refer to Downloading the Software from Salesforce for details.

Note

Use this procedure to only upgrade BMC firmware from 02.16.00 to 03.00.00 version. 

 

  1. Log on to the SBC BMC using the following credentials:
    Username: <username>
    Password: <default password>

    BMC 2.16 Login Screen

     
    The BMC Main screen is displayed. 

    BMC 2.16 Main Screen

  2. Click Remote Control. The Remote Control window is displayed. 

    BMC 2.16 Remote Control screen


  3. Click Power Control in the Options panel. The Power Control and Status window is displayed. 

    BMC 2.16 Power Control screen


  4. Choose Power Off Server - Orderly Shutdown option. 

    Note
    The BMC server must be shut down prior to performing a firmware upgrade.

    BMC 2.16 BMC Orderly Shutdown

     

  5. Click Perform Action to initiate the shutdown process.

    BMC 2.16 BMC Shutdown


  6. Click Maintenance tab. The Maintenance window is displayed.

    BMC 2.16 Maintenance Window


  7. Click Enter Update Mode. A message appears seeking your permission to proceed.

    BMC 2.16 Maintenance Window Confirmation Message


  8. Click OK to proceed. The BMC is now in the Upgrade Mode.

    BMC 2.16 Firmware Update window


  9. Browse and select the firmware file to upload. The firmware file to upgrade from 2.x to 3.x version should be a ".rom" file. For example: bmc5X00_v3.0.0-R0.rom file.

    BMC 2.16 Firmware File


  10. Click Upload Firmware. The BMC validates the selected file.
    Once the verification is complete, a message is displayed stating the result of the verification.

    BMC 2.16 Firmware Validation


  11. Click OK to proceed. The existing and the new BMC versions are displayed for validation.

    Note

    The BMC fails to upgrade if:

    • the selected version is same as the existing version.
    • the selected version is older than the existing version.
    • the selected firmware image is incorrect for the platform type. For example, selecting a SBC 7000 Series firmware file for an upgrade on SBC 5000 Series platform.

    BMC 2.16 Firmware Comparison


  12. Click Start Upgrade to initiate the upgrade process.
    A confirmation message appears seeking your permission to proceed with the upgrade.

    BMC 2.16 Upgrade Confirmation message

     

    Warning

    Once the upgrade process starts, do not close the screen.

    • If the window is closed or connectivity is lost before the upgrade starts, re-login to BMC GUI and reboot BMC. The BMC takes approximately 10 minutes to boot. Once the BMC boots up, re-login to BMC GUI and restart the upgrade process from step 1.
    • If the window is closed or the connectivity is lost during the upgrade process, wait for 20 minutes for the upgrade process to complete and try to access the BMC again. If you fail to gain access, contact the Sonus TAC team for assistance.


  13. Click OK to proceed. The BMC starts the firmware upgrade process.

    BMC 2.16 Upgrade Process


    Once the upgrade process is complete, the BMC reboots and a message appears requesting you to open a new browser window to access the BMC GUI.

    BMC 2.16 Upgrade Process Complete

  14. Exit the browser. 
  15. Clear the browser cache.
  16. Open a new browsing window to access the BMC GUI again.
  17. Access the same BMC IP address to reach the BMC login window. Observe the changes in the login window.

    In the new BMC version (03.00.00), the login window has some additional browser settings displayed.

    BMC 3.0 New Login Window


  18. Log on to the SBC BMC using the following credentials:
    Username: <username>
    Password: <default password>

    BMC 3.0 Main Screen


    The look and feel of the new BMC version (03.00.00) is different than the previous version. Explore the new BMC GUI at your leisure.

Upgrade BMC Firmware from 3.x Version for SBC 5400 and SBC 5000/7000 Series

The following procedure describes how to upgrade the BMC firmware from 3.x to 3.x versions (for example; from version 03.10.00 to version 03.11.00) using the Disc Image File.

  1. Log on to the SBC BMC using the following credentials:
    Username: <username>
    Password: <default password>

    BMC Login Screen

    The BMC main screen is displayed.

    SBC BMC Main Screen

  2. Click Firmware Update.

    BMC Firmware Update option


    The Firmware Update screen is displayed.

    BMC Firware Update screen

  3. Click Browse, and from the Open dialog browse to and select firmware-5XX0-V<release>.img firmware image. Refer to the Warning at the start of this page to make sure you have chosen the correct type of file for an upgrade. To determine the exact firmware version, refer to SBC Release Information for guidance.

    The chosen file displays next to the Browse button.

    Selected Firmware file

  4. Click Upload.

    Note

    The firmware image is approximately 17MB (for SBC 5000 Series) and 24MB (for SBC 5400 and SBC 7000 Series) and takes few minutes to upload based on the network.

    Note

    The BMC fails to upgrade if:

    • the selected version is same as the existing version.
    • the selected version is older than the existing version.
    • the selected firmware image is incorrect for the platform type. For example, selecting a SBC 7000 Series firmware file for an upgrade on SBC 5000 Series platform.

     

    The selected file is verified and the uploading process starts.

    Uploading Firmware file

  5. Once the file verification is complete, BMC seeks your permission to proceed further with the upgrade. Click Confirm to proceed.

    Caution

    This is a service affecting procedure and will power off the host side of SBC.

    Firmware verification and confirmation window


    Once upload starts, the actions performed are displayed in the same window along with the estimated time left to complete the process.

    Warning

    Once the upgrade process starts, do not close the screen.

    • If the window is closed or connectivity is lost before the upgrade starts, re-login to BMC GUI and restart the upgrade process from step1.
    • If the window is closed or the connectivity is lost during the upgrade process, wait for 20 minutes for the upgrade process to complete and try to access the BMC again. If you fail to gain access, contact the Sonus TAC team for assistance.

    Firmware upload status


    Once the update process is complete, a message is displayed stating the same.

    Firmware Update Complete message

  6. Click OK to complete the process.The BMC automatically restarts at this point.

  7. Close the existing browser window.

  8. Clear the browser cache and log on to the BMC GUI again. The updated BMC version is displayed on the BMC main screen.

  9. Log on to the BMC using the default credentials:
    Username: <username>
    Password: <default password>
     The SBC BMC compels you to change the password after a successful upgrade.

    This change is applicable only when the BMC is upgrade to version 03.13.00 and later versions.

    Change Default Password Window

  10. Click OK to proceed. The User Management window is displayed.

    You have an option to cancel the action. If cancelled, the password remains the same as the default password and you are allowed to continue to work on BMC. However, the warning message is displayed again on you next login to BMC. This reminder continues till the password is changed. To know more about how to successfully change the SBC BMC password, refer to Changing the BMC Password.

  11. Verify the upgraded version in the BMC main screen.
Note
For HA configuration, refer to Upgrade Flows for guidance.

  • No labels