In this section:
On SBC main screen, go to Configuration > System Provisioning > Category: Base Provisioning > Signaling Ports > Sip Sig Port. The Sip Sig Port window is displayed.
The Sip Sig Port can be checked for each Address Context or for each Zone or for all the Address Contexts and Zones created. Use the drop-down box to select the desired Address Context and Zone.
To edit any of the Sip Sig Ports in the list, click the radio button next to the specific Sip Sig Port name.
The Edit Selected Sip Sig Port window is displayed below.
Make the required changes and click Save at the right hand bottom of the panel to save the changes made.
To create a new Sip Sig Port, click New Sip sig Port tab on the Sip Sig Port List panel.
The Create New Sip Sig Port window is displayed.
The following fields are displayed:
Parameter |
|
---|---|
| A unique profile identifier. |
| The operational state of the SIP Sig Port:
|
| The administrative state of the SIP Signaling Port.
|
| Select from the drop-down list. |
| Specifies the V4 IP address in dotted decimal form (for example 10.11.12.0 24). |
| Specifies the V6 IP address in hexadecimal/colon form (for example, fd00:21:445:128::7880 64). |
| UDP/TCP port number of SIP Signaling Port (default is 5060). |
| Administrative state of the SIP Signaling Recorder Port. The values are:
Ensure that the |
Siprec | Specifies the administrative state of the SIP Signaling Recorder Port. Enable flag to use the port for recording using Siprec Protocol. The options are:
The SIPRec feature is controlled by a system-wide SBC license (SBC-SIPREC). If the license is not available, any SIPRec recording returned by a PSX is ignored. When |
| This object indicates the maximum time, in seconds, allowed for Unable to show "metadata-from": No such page "_space_variables" to establish an outbound TCP connection.This application level configuration has NO impact on any IP layer re-transmission of SYN. |
| DSCP value (0-63) for packets from this SIP Signaling Port. |
| The name assigned to this Transport Layer Security (TLS) profile. Must be 1 - 23 characters. |
| The transport protocols allowed on this signaling port as follows:
The SBC supports only UDP towards the recording server. |
| Specifies the name of the SCTP profile used for this Sip Signaling Port. |
Tcp Keepalive Timer | Specifies the number of seconds a TCP connection remains idle before TCP Keep-alive probes are sent out. A value of "0" disables this parameter. The value ranges from 60 to 7200 seconds and the default value is 0. |
Tcp Keepalive Interval | Specifies the number of seconds between TCP Keep-alive probes. The value ranges from 60 to 120 seconds and the default value is 60. |
Tcp Keepalive Probes | Specifies the maximum number of TCP Keep-alive probes to send until SBC decides that the connection is broken. The value ranges from 1 to 20 and the default value is 2. |
Mask Portfor RCB | This flag is used to fetch the RCB value for a user, When this flag is enabled, the RCB value is fetched using only the source IP address and not the source port for generating the hashKey. The options are:
The flag |
Mask Ip Addressfor RCB | This flag is used to fetch the RCB value for a user, When this flag is enabled, the RCB value is fetched using only the
The flag |
Action | Use this object to specify a clearing action when the SIP Signaling Port goes out-of-service (OOS). Calls can be forcefully cleared or allowed to dry up in out-of-service mode.
|
|
Use this parameter to specify the time (in minutes) until which existing calls are allowed to complete in out-of-service mode with dry up action. (range: 1-1440 / default = 60) When
Once the dryup timer expires, SBC tears down ongoing calls and all ongoing SIP Registrations and non-call related dialogs are cleared internally. The SIP Signaling Port is then moved to OOS state where no SIP messages are admitted. |
To copy any of the created Sip Sig Port and to make any minor changes, click the radio button next to the specific Sip Sig Port to highlight the row.
Click Copy Sip Sig Port tab on the Sip Sig Port List panel.
The Copy Selected Sip Sig Port window is displayed along with the field details which can be edited.
Make the required changes to the required fields and click Save to save the changes. The copied Sip Sig Port is displayed at the bottom of the original Sip Sig Port in the Sip Sig Port List panel.
To delete any of the created Sip Sig Port, click the radio button next to the specific Sip Sig Port which you want to delete.
Click Delete at the end of the highlighted row. A delete confirmation message appears seeking your decision.
Click OK to remove the specific Sip Sig Port from the list.