In this Section:
In this section:
SecureLink (also known as Sonus Gatekeeper) is a third party remote management tool used extensively by the Sonus Support team. SecureLink allows Sonus dedicated remote connectivity into your devices while providing you with the latest in security and audit ability. This object provides the ability to view the DNS IP address, SecureLink Gatekeeper version, edit registration code and also the status and results of the host name lookup test and direct connectivity test of the SecureLink access test.
From the SBC main screen, navigate to Administration > System Administration > SecureLink. The SecureLink window is displayed.
The security of the SBC is enhanced to restrict the port 4680 to "localhost". With this enhancement, you cannot access the Gatekeeper (web-based SecureLink GUI, served from the port 4680) remotely using the management port of the SBC. Access to the Gatekeeper tool through your browser is not required to configure SecureLink.
To install and/or uninstall SecureLink, click Install SecureLink and Uninstall SecureLink respectively. By default, SecureLink is bundled with the SBC application package. When you install the SBC application, SecureLink is automatically installed as part of the application installation.
To uninstall SecureLink:
To setup SecureLink, perform the following:
Click Enable Gatekeeper Access. The Gatekeeper access status is displayed as enabled
in the screen.
Do not enter the same registration code on both the SBCs in an HA pair. If you do, only one SBC is enabled at a time.
After the access is enabled, to test the connectivity to the server, allow access on port 22 to securelink.sonusnet.com .
Click Test SecureLink Access to perform the Host name lookup test and Direct connectivity test.
The Host name lookup test and Direct connectivity test field status change to In Progress
.
Once the host name lookup and direct connectivity test is successful, you can access the SecureLink application.
To disable Gatekeeper Access, perform the following:
Click Disable Gatekeeper Access.
It may take a while to disable Gatekeeper Access.
To collect the logs for troubleshooting SecureLink issues:
Click Gatekeeper Logs.
Gatekeeper logs are available in the /var/log/sonus/securelink
directory of the SBC. To access the logs, root
level privileges are required.