You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 6 Next »

 

This section describes upgrading the

Unable to show "metadata-from": No such page "_space_variables"
application in a standalone or HA configuration using the EMA. Beginning with 5.0 release, the Platform Manager is integrated into the EMA and hereafter referred to as EMA Platform Mode. Thus, post 5.0 SBC application upgrades are performed using the EMA.

Procedure

Warning

 This procedure is service impacting.

The BIOS firmware upgrade is not part of SBC application upgrade in

Unable to show "metadata-from": No such page "_space_variables"
platforms. Refer to Upgrading SBC 7000 Series Firmware for more information.

The following procedure describes the 

Unable to show "metadata-from": No such page "_space_variables"
application upgrade using the EMA (Non-LSWU):

  1. Download the SBC application package from the Salesforce customer portal to your local folder on a PC or remote server. To know more on how to download files, refer to Downloading the Software from Salesforce.
  2. Validate the SBC md5 checksum using the checksum calculator. See Validating MD5Sum with 'Checksums Calculator' for guidance.
  3. Launch EMA.

  4. Navigate to Monitoring > Dashboard > System and Software Info to verify the software and HA peer status for both active and standby servers.

    System and Software Info Screen for Active Server

    System and Software Info Screen for Standby Server

  5. Navigate to Administration > System Administration > File Upload to upload the SBC application package to active and standby SBC servers.

    1. Click File Upload tab.

      File Upload Screen

    2. Click Add Files to Queue.

    3. Browse the SBC application package files in the File Upload screen and click Open 

      Selecting SBC application package

        

    4. The files are listed in Upload Queue section. Click Upload All Files. The file upload starts.

      Uploading SBC package

       
       

      Files on SBC

       

       

    5. Repeat step a through e for standby SBC server.
  6. Stop the application on active server using Administration > System Administration > Platform Management > Stop SBC Application.

    Stopping SBC Application in Active Server

  7. The stop application is a service affecting operation. Click OK to continue the stop operation.

    Confirming Stop SBC Application

  8. The application is stopped on the active server.

    Application Stopped on Active Server

  9. Launch the Platform Manager on the standby server.

    After stopping the application on the active server (WFDSBC01a), the automatic switchover happens and standby server (WFDSBC01b) becomes active.

  10. Stop the application on standby server using Administration > System Administration > Platform Management > Stop SBC Application.

    Stopping SBC Application on Standby Server

  11. The stop application is a service affecting operation. Click OK to continue the stop operation.

    Confirming Stop Application

  12. The application is stopped on the standby server.

    Application Stopped on Standby Server

  13. From the EMA of initial active server (WFDSBC01a), click Administration > System Administration > Software Install/Upgrade tab.

  14. Select the SBC Package Name to upgrade, and click Upgrade Software.

    Selecting SBC Package

     
  15. The signature file of the SBC package verifies the integrity of the package contents before proceeding with the SBC installation.

    Verifiying Package Integrity

     
  16. Select Offline Upgrade from the upgrade type and click Start Upgrade.

    Selecting Offline Upgrade

     
  17. The upgrade process starts on the active server (WFDSBC01a) and displays the upgrade status on Upgrade Log section.

    Copying Package to Staging

    Extracting Package Contents

    Performing Pre-install Checks

    Performing Pre-Install Checks

    You may lose connectivity to browser session as the server goes for reboot.

    This process takes approximately 45 minutes to complete on a single server.

    Once the upgrade is successful, clear the browser cache prior to accessing the SBC EMA.

  18. Log on to the EMA using the default credentials.

    Logging On to EMA Platform

    Logging On to EMA Platform

  19. Verify the SBC installation status on the Administration > System Administration > Software Install/Upgrade screen.

    Continuing the SBC Upgrade


    Wait until the SBC upgrade is complete.

    Completing SBC Upgrade



  20. Verify the SBC application status on the Administration > System Administration > Platform Management screen.

    Verifying Active SBC Status

    Once all the SBC process starts running, continue upgrading the standby SBC server.

  21. Follow the step 13 through step 19 to perform upgrade on the standby server (WFDSBC01b).

  22. Verify the SBC application status on the Administration > System Administration > Platform Management screen.

    Verifying Standby SBC Status

  23. Verify the Firmware, ConnexIP OS and SBC application in Monitoring > Dashboard > System and Software Info.

    System and Software Information for Active Server

    System and Software Information for Standby Server

  24. Verify the system sync status is in Sync Completed state in All > System > Sync Status.

    System Sync Status

     

    End of Procedure

     

     

  • No labels