Some Application software changes are delivered as patch, which is substantially smaller than a firmware upgrade. A Patch is always based on specific Major or Minor release, so you must apply patch only to the specific Base Software Version for which it is designed. Unlike
Unable to show "metadata-from": No such page "_space_variables"
Unable to show "metadata-from": No such page "_space_variables"
software/firmware versions, patches can be applied to currently active partition or the non-active application partition. All system configuration is preserved when you apply a Patch.
Applying a patch to the active (running) partition may disconnect your active calls.
If you uploaded the patch to the currently active partition, the system restarts the patched components. Depending on which components were patched, this process may disrupt currently active calls.
Unable to show "metadata-from": No such page "_space_variables"
recommends that you only apply patches to inactive partitions or to active partitions during a planned service outage.
To upload a SBC 1000/2000 firmware patch:
- Download the patch from the Ribbon SBC Edge Download Center (or from your
Unable to show "metadata-from": No such page "_space_variables"
service representative for more information) - In the WebUI, click the Settings tab.
In the left navigation pane, go to System > Software Management > Application Partitions.
- Click the expand () in the row of the partition to which you want to apply the patch.
Click the Upload Patch link - a popup window will appear:
- Under Select File, click the Browse button and select the patch file to upload.
- Click OK to upload the patch.