For information on power connection requirements for the
Unable to show "metadata-from": No such page "_space_variables"
system, see
Power Connection Requirements.
The
Unable to show "metadata-from": No such page "_space_variables"
power supplies must be replaced with Ribbon-provided units only.
Ribbon SBC 1000 Power Supply
Specifications
The
Unable to show "metadata-from": No such page "_space_variables"
system comes equipped with a single power supply which complies with the following specifications:Item | Specification |
---|
Input Voltage | AC: 100-240 VAC Nominal, Auto-switching, 47-63 Hz |
AC Maximum Input Current | 1.25A at 115VAC and 0.63A at 230VAC |
AC Input Voltage Range (nominal) | 100-127VAC and 200-240VAC |
Output | +12V/10A |
Max Power Consumption | 144 |
LED Status Indicator
There are no visible Power Supply LEDs on the
Unable to show "metadata-from": No such page "_space_variables"
SBC 1000.
Ribbon SBC 2000 Power Supply
Specifications
The
Unable to show "metadata-from": No such page "_space_variables"
system comes equipped with either a single power supply, or dual redundant power supplies which comply with the following specifications:Item | Specification |
---|
Input Voltage | AC: 100-240 VAC Nominal, Auto-switching, 47-63 Hz |
AC Maximum Input Current | 5A at 115VAC and 2.5A at 230VAC |
AC Input Voltage Range (nominal) | 100-127VAC and 200-240VAC |
Output | 300 W-AC: +5V/20A, +12V/24A, -12V/0.6A, +3.3V/20A, +5VSB/3A |
Max Power Consumption | 300 watts |
LED Status Indicator
The
Unable to show "metadata-from": No such page "_space_variables"
power supplies include a LED status indicator on the back of the unit. The following table explains the meaning of the various LED Status states.
LED Status | Power Supply Status Description |
---|
Solid Green | Normal (AC on, DC power on) |
Blinking Green | Standby (AC on, DC standby on, DC power off) power to the Unable to show "metadata-from": No such page "_space_variables" SBC 1000/2000 main board is off |
Solid Red | Alarm Condition |
Blinking Red | Fan Failure |
Off | AC Failure |
Safety Requirements
The
Unable to show "metadata-from": No such page "_space_variables"
power supplies are tested and certified to meet UL / cUL / IEC 60950-1 safety requirements.