Sonus-provided SFP/SFP+ modules must be used to guarantee proper operation of the external ports. Failure to follow this recommendation may cause permanent damage to the system.

The 

Unable to show "metadata-from": No such page "_space_variables"
supports the following Small Form-factor Pluggable (SFP/SFP+) transceivers. SFPs (SFP/SFP+) are Customer Replaceable Units (CRU).

The following SFP transceivers are compatible with 

Unable to show "metadata-from": No such page "_space_variables"
Management ports:

1Gb SFP Parts

Transceiver TypeProduct CodeDescription
CopperSBC-SFPCOPPER-1GGIGE, 1000 BASE-T SMALL FROM PLUGGABLE (SFP)
Must use one of the following:
 ManufacturerManufacturer Part Number
 AVAGO TECHNOLOGIESABCU-5710RZ-SN1
 AVAGO TECHNOLOGIESABCU-5740RZ-SN1
 BROADCOMABCU-5740RZ-SN1
 FINISARFCLF8521P2BTL-SS
Single-mode fiberSBC-SFPSM-1GGIG-E, SINGLE MODE, FIBER OPTIC TRANSCEIVER MODULE, LC, SMALL FORM PLUGGABLE (SFP), 10KM 1310NM, DMI
Must use one of the following:
 ManufacturerManufacturer Part Number
 AVAGO TECHNOLOGIESAFCT-5715PZ-SN1
 BROADCOMAFCT-5715PZ-SN1
 FINISARFTLF1318P2BTL-SS
 FINISARFTLF1318P3BTL-SS
Multi-mode fiberSBC-5400-SFPMMGIG-E, MULTIMODE, FIBER OPTIC TRANCEIVER MODULE, LC, SMALL FORM PLUGGABLE (SFP), 300M
Must use one of the following:
 ManufacturerManufacturer Part Number
 AVAGO TECHNOLOGIESAFBR-5715PZ-SN1
 BROADCOMAFBR-5715PZ-SN1
 FINISARFTLF8519P2BNL-SS
 FINISARFTLF8519P3BNL-SS
The following SFP+ transceivers are compatible with 
Unable to show "metadata-from": No such page "_space_variables"
Media and HA ports:

10Gb SFP+ Parts

Transceiver TypeProduct CodeDescription
Single-mode fiberSBC-SFPSM-10G10.3 GB/S, SINGLE MODE, FIBER OPTIC XCVR, LC, SFP, 10KM 1310NM, DM
Must use one of the following:
 ManufacturerManufacturer Part Number
 AVAGO TECHNOLOGIESAFCT-709SMZ-SN1
 AVAGO TECHNOLOGIESAFCT-739SMZ-SN1
 BROADCOMAFCT-739SMZ-SN1
 BROADCOMAFCT-709SMZ-SN1
 FINISARFTLX1471D3BCL-SS
Multi-mode fiberSBC-SFPMM-10G10.3 GB/S, MULTIMODE, FIBER OPTIC XCVR, LC, SFP, 300M 850NM, DMI GIG-E, SINGLE MODE, FIBER OPTIC TRANSCEIVER MODULE
Must use one of the following:
 ManufacturerManufacturer Part Number
 AVAGO TECHNOLOGIESAFBR-709SMZ-SN1
 BROADCOMAFBR-709SMZ-SN1
 FINISARFTLX8574D3BCL-SS
 FINISARFTLX8571D3BCL-SS

Parts and Tools Required

The following items are needed to install/replace a SFP/SFP+ device:

  • Electrostatic discharge (ESD) strap
  • Replacement SFP/SFP+ transceivers.

To prevent damage from electrostatic discharge, an ESD strap is provided in the accessory kit. See Connecting Electrostatic Discharge Wrist Strap on SBC 7000 to install it.

Replacing the SFP/SFP+

To replace the SFP/SFP+:

  1. Attach an Electrostatic Discharge wrist strap by using the ESD grounding point on the back panel of the chassis. Follow the instructions in the section Connecting Electrostatic Discharge Wrist Strap on SBC 7000.
  2. Disconnect the fiber optic and/or Cat 5 cables, as appropriate, from media ports (Media 0-4) and HA ports (HA 0-1).
  3. Disengage the SFP/SFP+ transceiver from

    Unable to show "metadata-from": No such page "_space_variables"
    . The method used to disengage the SFP/SFP+ transceiver will vary according to the manufacturer. For example, hold the wire latch and move it downwards to the horizontal position and pull it outwards.

  4. Insert the Sonus-approved SFP/SFP+ transceiver into the desired socket and ensure that the latch mechanism engages.

  5. Reconnect the fiber optic and/or Cat 5 cables, as appropriate, to media and HA ports.
  6. Verify LEDs above the part are flashing indicating link status and data activity.
  7. Verify port functionality by using the application.

CRU Storage

All 

Unable to show "metadata-from": No such page "_space_variables"
CRUs are shipped in electrostatic discharge bags and should be handled using appropriate ESD precautions.

The storage environment for these CRUs are:

  • Humidity must be less than 95% (non-condensing).
  • Temperature must be between -40C and +70C.

 

The ESD Susceptibility symbol warns of the presence of Sonus devices susceptible to electrostatic discharge. Do not handle equipment without wearing a properly grounded ESD wrist strap.