Excerpt

Use this window

...

to configure signaling timers for the node.

To View and Edit H323 Sig Timers

...

From the EMA main screen,

...

choose a path:

Configuration > Profile Management > Category: Signaling Timers > H323 Sig Timers

Image Added

The H323 Sig Timers window is displayed.

...

1Profile Management - Signaling Timers -
Caption
0Figure


H323 Sig Timers

 Image Removed

...

Parameters:

Caption
0Table
1H323Sig Timers Parameters
ParameterLength/Range
Parameter
Description
Establish
Specifies the H225
0-127

The H.225 signal channel establishment timer (in seconds).

The value ranges from 0 to 127 seconds and the

The default value is 4

seconds

.

Tcp
TCP Connect
0-127

The

Specifies the

TCP connect timer (in seconds).

The value ranges from 0 to 127 seconds and the

The default value is 3

seconds

.

T301
Specifies the
0-65535

The T301 call timer (in seconds).

The value ranges from 0 to 65535 seconds and the

The default value is 180

seconds

.

T302
Specifies the
0-127

The T302 call timer (in seconds).

The value ranges from 0 to 127 seconds and the

The default value is 15

seconds

.

T303
0-127

The

Specifies the

T303 call timer (in seconds).

The value ranges from 0 to 127 seconds and the

The default value is 4

seconds

.

T304
Specifies the
0-127

The T304 call timer (in seconds).

The value ranges from 0 to 127 seconds and the

The default value is 20

seconds

.

T310
0-127

The

Specifies the

T310 call timer (in seconds).

The value ranges from 0 to 127 seconds and the

The default value is 10

seconds

.


Make the required changes and

...