Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.


Panelexcerpt

In this section:

Table of Contents
maxLevel2

...

Use this screen to configure DTMF digit detection attributes for a Digit Profile.

To View and Edit

...

DTMF Detect

On the SBC main screen, go

...

to Configuration

...

 > Profile Management

...

 > Category: Digit

...

Profiles > Digit Profiles

...

 > DTMF Detect.

Select the desired Digit Profile from the drop-down list to view its respective

...

DTMF Detect parameters.

The

...

DTMF Detect window is displayed.

...

Profile Management - Digit Profiles -

...

DTMF Detect

Image Modified

The following fields are displayed:

...


DTMF Detect Parameters

ParameterLength/RangeDescription
Min Power

...

-45 dBm to -25 dBm

The minimum power level (in dBm

...

) for digit detection.

...

Default = -45.

Min On Duration

...

25 to 80 ms

The minimum tone duration (in milliseconds

...

) for digit detection. The value must be in increments of

...

5 ms. Default = 35.

Min Off Duration

25 to 80 ms

Specifies minimum tone duration in milliseconds required for digit detection. The value must be in increments of 5ms.

...

Default = 25.

Frequency Range

N/A

Specifies frequency tolerances for digit detection. The value represents accept and reject ranges. Frequencies detected within the

...

acceptable range will result in digit detection.

Frequencies detected outside the reject range will not result in digit detection.

...

...

  • Narrow
  • Medium (default)
  • Wide
  • Wider
Twist Cutoff

4 to 12 dB

Specifies the ratio of high group power to low. Twist ratios below the twist cutoff will result in digit detection. Twist ratios above the twist cutoff will result in digit rejection.

...

Default = 8 dB.

Note

This parameter

...

applies to DTMF digit detection only.


Make the required changes and

...