SBC Power Requirements

After installing the

Spacevars
0model5
chassis in a rack and attaching necessary cables, you are now ready to install power and ground cables and apply power to the
Spacevars
0model5
. The 
Spacevars
0model5
is capable of dual redundant AC or DC power.

The standard 

Spacevars
0model5
platform is shipped with one power supply. A second power supply may be added for redundancy at any time. Please contact your sales representative for more information.

Warning
Connect the chassis ground lug to the SBC chassis before connecting power.
Caption
0Table
1


SBC 5400 Power Requirements

ConfigurationAC Input (W)
 


DC (W)




AC Low LineAC High Line

Minimum:  90 Vrms
Nominal:  100-120 Vrms
Maximum:  140 Vrms

Minimum:  180 Vrms
Nominal:  200-240 Vrms
Maximum:  264 Vrms

Minimum:  40 Vdc
Nominal:  48 Vdc
Maximum:  60 Vdc

AmpsWattsAmpsWattsAmpsWatts
Spacevars
0model5
 without DSP Card
5.75122.951612.6502
Spacevars
0model5
 + 1 DSP Card
6.45763.258214.0559
Spacevars
0model5
 + 2 DSP Cards
7.26443.664714.9594
Spacevars
0model5
 + 3 DSP Cards
7.87023.970217.0678
Spacevars
0model5
 + 4 DSP Cards
8.57614.276317.3692
Note

This is estimated power consumption. All power measurements were taken with fans running at high speed.

Anchor
grounding_chassis
grounding_chassis

Grounding
Spacevars
0model5
Chassis

The following procedure explains how to ground the 

Spacevars
0model5
platform to local earth using a 7/16 inch wrench:

  1. Locate the chassis grounding studs on the back of the chassis.
  2. Attach the two hole chassis ground lug PN 300-30016 to the

    Spacevars
    0model5
    using two flat washers PN 510-00057, two split lock washers PN 510-00056, and two hex nuts PN 511-00046 as shown in the following figure.

    Caption
    0Figure
    1Chassis Grounding Lug Location

    Image Removed

    Image Added

  3. Secure the other end of the grounding cable to the earth ground in the building. You can secure the grounding cable to a proper grounding point on the rack, as long as the rack is properly grounded to the earth ground in the building.
 
Note

Connect the chassis to local earth ground so that any possible charge is carried off to the earth thus eliminating the risk of shock.

Routing the Power Cables

Ribbon recommends to route the power cables so that the top power supply cables connect from above and the bottom power supply cables connect from below. This prevents one power supply cable from getting in the way of the other one in case it needs to be removed individually.

Connecting to AC Power

Connecting to AC Power Source and Powering On

The following procedure explains how to connect to the AC power and powering on the switch:

  1. For each AC power supply, insert the supplied AC power cord female connector to the power supply AC receptacle at the rear of the chassis (shown in the following figure).

    Caption
    0Figure
    1SBC 5400 Chassis AC Power Location

    Image Removed

    Image Added

  2. Connect the supplied power cords to the local AC power source.
  3. Turn on your local AC power source.

In a dual-redundant power supply configuration, the power supplies are hot-swappable meaning that it may be replaced without removing the power supply of SBC platform (provided that the redundant power supply is operational).

Note
titleImportant
Before replacing a power supply in a redundant power supply configuration, verify the status of the redundant power supply. The “POK” LED status must be “solid green”. Removing the power supply when the redundant supply does not show a solid green status, may cause the system to power down. Contact Ribbon customer support if required.

The following table describes the status of AC power supply.

Caption0Table1


AC power supply LED states

ConditionLED Status (Green/Amber)
Standby ON, Main Output OFF, AC PresentBlinking Green
Standby ON, Main Output ONSolid Green
Main Output OCP, UVP, OVPBlinking Amber
FAN Fail, OTP, Standby OCP/UVPAmber

Disconnecting from AC Power Source

The following procedure explains how to disconnect from your local AC power source:

  1. Perform a graceful shutdown of the
    Spacevars
    0model5
    system through BMC.
  2. Turn off your local AC power source.
  3. Remove the power cord.

Connecting to DC Power

Connecting to DC Power Source and Powering On

The following procedure explains connecting an

Spacevars
0model5
power supply to the DC Power and power on the switch. If two power supplies are installed, both need to be connected to power before powering up the switch.

Note

Identify the correct size fuse(s) for your configuration and wire gauge before applying DC power to a switch. Also, ensure to switch off the power supply before installing the cables.

  1. Remove the clear plastic terminal cover and set it aside.
  2. Check the chassis ground is connected to the 2-post terminal lug next to the power supply bay. See Grounding SBC 5400 Chassis topic above.
  3. Connect ground cable (green) to the screw located above the DC power terminal posts as shown in the below figure:

    Pagebreak

    Caption
    0Figure
    1SBC 5400 DC Terminal Connections

    Image Removed

    Image Added

  4. Use a Voltmeter to verify that no voltage is present on DC input power cables.
  5. Attach the DC return cable (black) to the Return terminal.
  6. Attach the -48V cable (red) to the -48V terminal.
  7. Reattach the clear plastic terminal cover.
  8. If applicable, attach the other end of the supplied DC power cables to DC power source.

    Warning

    Do not apply DC power to the DC Power supply prior to hot-inserting the supply into the chassis.

  9. Turn on DC power source.

In a dual-redundant power supply configuration, the power supplies are hot-swappable meaning that it may be replaced without powering down the 

Spacevars
0model5
  platform (provided that the redundant Power Supply is operational).

Note
titleImportant
Before replacing a power Supply in a redundant power supply configuration, verify the status of the redundant power supply. The “POK” LED status must be “solid green”. Removing the power supply when the redundant supply does not show a solid green status, may cause the system to power down. Contact Ribbon Customer Support if required.

The following table describes the status of DC power supply.

Caption0Table1

DC

power supply

Power Supply LED

states

States

ConditionLED States (Green/Amber)
No DC Power to all PSUOFF
DC present/Standby Outputs ON, Main Output OFF Blinking Green
Power Supply DC Outputs ON and OKSolid Green
Main Output Failure (OCP, OVP, UVP)Blinking Amber
Fan Fail, OTP, Standby Output OCP/UVPSolid Amber

Pagebreak

Disconnecting the DC Power Source

The following procedure explains how to disconnect DC power from 

Spacevars
0model5
chassis :

  1. Perform a graceful shutdown of the 
    Spacevars
    0model5
    system through BMC.
  2. Turn off the local DC power source.
  3. Remove the clear plastic terminal cover and set it aside.
  4. Remove the DC power cables from the terminals, and re-attach the screws.
  5. Remove the ground cable from the power supply, and re-attach the screw.
Warning

Do not remove the DC Power supply without first turning off the power to the power supply being removed from the chassis.

Removing the Power Supply

Warning

Remove DC power from the power supply and remove the power cables from power supply before attempting this procedure.

To remove the AC or DC power supply from the chassis, perform the following steps:

  1. Push the green or black integrated lever towards your left to disengage the power supply module.
  2. Pull the power supply out of the power supply slot.

Refer to the following figures for integrated lever locations:

Caption0Figure1

SBC 5400 DC Power Supply Integrated Lever

Image Modified

Caption0Figure1


SBC 5400 AC Power Supply Integrated Lever

Image Modified