Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Add_workflow_for_techpubs
AUTH1UserResourceIdentifier{userKey=8a00a0c86e9b2550016ec54396b5000a, userName='null'}
JIRAIDAUTHSBX-123538
REV5UserResourceIdentifier{userKey=8a00a0c86e9b2550016ec54396b5000a, userName='null'}
REV6UserResourceIdentifier{userKey=8a00a0c86e9b2550016ec54396b5000a, userName='null'}
REV3UserResourceIdentifier{userKey=8a00a0c86e9b2550016ec54396b5000a, userName='null'}
REV1UserResourceIdentifier{userKey=8a00a0c86e9b2550016ec54396b5000a, userName='null'}


Panel

In this section:

Table of Contents
maxLevel2



Tooltip
tipUse ESD protective device

The 

Spacevars
0series2
chassis configured for AC power is shipped with two dual redundant AC power supplies. Dual redundancy means the power supplies are hot-swappable. In other words, you can replace a power supply without powering down the
Spacevars
0series2
platform (provided that the redundant Power Supply is operational).

The AC power supply Customer Replaceable Unit Ribbon Part Number is 451-01043 and the product codes are:

  • SBC-7000-PSUAC
  • SBC-7000-PSUAC-SPARE

The figure AC Power Supply below depicts a dual redundant configuration:


Info
titleNote

The Power OK (POK) LEDs are displayed at the right hand bottom of the power supply panel (marked in yellow).


Info
titleNote

Before replacing a Power Supply in a redundant power supply configuration, verify the status of the redundant power supply. The Power OK (POK) LED status must be solid green. Removing the Power Supply when the redundant supply does not show a solid green status, may cause the system to power down. Contact

Spacevars
0company
Customer Support if required.


Parts and Tools Required

Tooltip
tipESD protective device

To replace a faulty power supply, the following items are needed:

  • Electrostatic discharge (ESD) strap
  • Replacement AC power supply
Info
titleNote

To prevent damage from electrostatic discharge, use the provided ESD strap when handling the power supplies.

Replacing an AC Power Supply

Perform the following procedure to replace a Power Supply:

  1. Verify the Power OK (POK) green LED of the redundant Power Supply is lit.
  2. Attach an Electrostatic Discharge wrist strap to the ESD grounding point on the back panel of the chassis, and place the other end around your wrist. Follow the instructions provided in the section Connecting Electrostatic Discharge Wrist Strap on SBC 7000.
  3. Move the release lever to the left and pull the Power Supply out from the rear of the chassis.



  4. Install the replacement AC Power Supply to the 

    Spacevars
    0series2
    chassis by sliding it forward until you hear the latch click in place.
    The AC Power Supply has two LEDs per each AC Line, OK and Power OK (POK).

  5. The AC Line OK is turned on when the power supply is connected to the AC power source to verify the existence of the AC power. The Power OK (POK) indicates that the power supply is enabled and it is supplying the 

    Spacevars
    0series2
    with power.

  6. Observe that the POK green LED on the newly-inserted Power Supply is solid green. It takes maximum 1 minute for the Power Supply to turn on.
  7. From the application, ensure that no Power Supply alarms are generated.

Info
titleNote

 Whenever a supply is replaced or AC power has been removed and reapplied, it may take up to one minute for the supply to turn on.

CRU Storage

Tooltip
tipESD protective device

All 

Spacevars
0series2
CRUs are shipped in electrostatic discharge bags and must be handled using appropriate ESD precautions.

 The storage environment for these CRUs are:

  • Humidity must be less than 95% (non-condensing)
  • Temperature must be between -40C and +70C.


Include Page
SBXDOC110:_ESD_footnoteSBXDOC110:
_ESD_footnote