Page History
Add_workflow_for_techpubs | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Type: MAJOR
Object ID | 1.3.6.1.4.1.2879.2.8.1.2.1.19.0.4 |
Description | This alarm indicates that the License Manager has rejected the registration request. |
Repetition | Repeats for each occurrence. |
Event Codes | EVENT_LICENSE_MANAGER_SERVER_REGISTRATION_FAILED |
Instance Fields |
|
Action | Check the logs on the License Manager and correct the issues listed. |
Impact | The SBC |
cannot register with the |
|
|
Spacevars | ||
---|---|---|
|
| ||||||||
Clearing | automatic; sonusCpLicenseManagerRegistrationSucceeded |
Overview
Content Tools