These statistics are available on a real time (CURRENT) or on a historical (INTERVAL) basis. By default, the 

Spacevars
0series4
 maintains four 15-minute intervals of data, so that at any time the previous hour's data is available. However, you may configure the number of intervals and the size of the intervals on the
Spacevars
0series4
.

On the SBC main screen, go to All > System >Interval Statistics. The Interval Statistics window is displayed.

Figure 1: System - Interval Statistics

...

The following fields are displayed:

Table 1: Interval Statistics parameters

Parameter

Description

Time Interval

Specifies the range of the timer interval in minutes that can be used by the configuration management for activities such as to measure the statistics of certain resources. Must be 5-60 (minutes), The time interval (in minutes) for interval statistics data. Range: 5-60 minutes; default is 15.

Include Page
_Interval Stats Must Match RAMP
_Interval Stats Must Match RAMP

Number of Past
Intervals

Specifies the range of the The number of past interval that can be configured to configure for retrieving the statistics data. Must be Range: 1-12 ( intervals), ; default is 4.
Max File Retention PeriodSpecifies the The maximum retention period for statistics files stored on disk. The value ranges from 60 to 1440 minutes and the default value is 60 minutes.
Node Id

The

Spacevars
0model3

Specifies the EMS

configured nodeID for this system to be used as part of the file name when writing the statistics to the file. The node ID is part of the file name for the PMS tar files. The default value is 0 which states as "unassigned".

Call Count Time IntervalSpecifies the The time interval for interval statistics of call Count data. The value ranges from 5 to 60 minutes and the default value is 15 minutes.

Make the required changes and click Save at the right hand bottom of the panel to save the changes made.