The BMC web application allows provisioning of primary and secondary host management interfaces. When the host management interfaces are configured, a direct link from the BMC is enabled to the EMA for installing and upgrading the
Spacevars | ||
---|---|---|
|
Use the following procedure to configure the primary and secondary host management interfaces:
Log on Logon to the SBC BMC GUI using the IP address configured in the previous section. The SBC BMC main screen appears.
Caption 0 Figure 1 BMC Main Screen Navigate to Configuration > Platform Management Network tab. The Platform Management Network Settings screen is displayed.
Caption 0 Figure 1 Configuration Screen Info title Note A message appears to enter the management IP addresses for the first time installation.
Caption 0 Figure 1 Warning Message - Click OK.
Configure the following network settings for both the Management Interface 0 and 1.
- IPv4 Address or/and IPv6 Address
- Prefix
- Default GatewayClick Save.
Caption 0 Figure 1 Platform Management Network Settings Info title Note infoWhen coming from an application software release prior to SBC 3.1.x, an IPv4-mapped IPv6 address is applied as an unusable placeholder in the IPv6 management address, this mapped address must be removed or set to a valid IPv6 address when updating the management addresses via BMC.
Warning | |
---|---|
|
...
|
...
Once you |
...
update a new Management IP address |
...
from the BMC and click Save, a warning message displays informing you to reinstall the SBC application software |
...
. If you update the Management IP using CLI |
...
/EMA or RAMP, the change will |
...
automatically update in the BMC and an application re-installation is not required. |
...
...
Warning message: