Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Add_workflow_for_techpubs
AUTH1UserResourceIdentifier{userKey=8a00a0c86820e56901685f374974002d, userName='null'}
JIRAIDAUTHSBX-118835
REV5UserResourceIdentifier{userKey=8a00a02355cd1c2f0155cd26cb8305e9, userName='null'}
REV6UserResourceIdentifier{userKey=8a00a02355cd1c2f0155cd26cb8305e9, userName='null'}
REV3UserResourceIdentifier{userKey=8a00a02355cd1c2f0155cd26cb1f0553, userName='null'}
REV1UserResourceIdentifier{userKey=8a00a02355cd1c2f0155cd26c7480005, userName='null'}

TypeCRITICAL

Object ID1.3.6.1.4.1.2879.2.8.1.2.1.19.0.6

Description

This alarm indicates that the SBC was unable to register with the License Manager during the grace period.

Repetition

Repeats for each occurrence.

Event Codes

EVENT_LICENSE_MANAGER_REGISTRATION_PERIOD_EXPIRED

Instance Fields

  • sonusAlarmNodeID
  • sonusAlarmLevel
  • sonusAlarmSequenceId
  • sonusAlarmTime
  • sonusAlarmDescription
  • sonusLicenseManagerGracePeriod

Action

Check the previous alarms regarding registration failures and take the actions indicated.

Reconnect the SBC to the managing EMS/RAMP instance.

Impact


Excerpt

The SBC has been disconnected from the managing EMS/RAMP for an extended period, resulting in the SBC operating in an unsanctioned manner from a licensing perspective. Reconnect the SBC to the managing EMS/RAMP instance. Contact

Spacevars
0company
 Global Product Support for more information regarding the need for the SBC to remain in constant contact with the managing EMS/RAMP instance.


Available_since
Release10.1.2

Clearing

automatic; sonusCpLicenseManagerRegistrationSucceeded