The Read Commands Output table displays all added read commands.

Mobile Diagnostics

Image Added


Limit mobile module to a specific FREQ or cell

This feature limits the mobile module to a specific FREQ or cell. The following information is required to execute this:

  1. Enter the Type, Name, AT command as shown in the below table, to read current mobile info.

    Type NameAT commandShow Lines

    user-defined

    nwscanmode

    AT+QCFG=[nwscanmode]

    2

    user-defined

    serving_cell

    AT+QENG=[servingcell]

    2

    user-defined

    lock_the_cell

    AT+QNWLOCK=[common/lte]

    2



  2. The read command output table displays the newly added read commands as shown below:

    Image Added
  3.  In the Query Command set the Type to Advanced send command and enter AT+QCFG=[nwscanmode],3 in the AT command to Send.

    Image Added

    Note

    This should be done before locking the LTE cell.


  4. To lock the mobile module to a specified FREQ or cell, in the Query Command, set the Type to Advanced send command, and enter AT+QNWLOCK= [common/lte],2,<EARFCN>,<PCI> in the AT command to Send.

    Note

    This approach locks mobile interface only up to one cell. Insert SIM card before the locking cell procedure.


  5. Verify whether the "nwscanmode" and "lock the cell" is changed in the Read Commands Output table. 

    Image Modified