Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Type: MAJOR
                                                                                                                                                                                                                                                                                                                  

Object ID1.3.6.1.4.1.2879.2.8.1.4.1.1.0.1

Description

This alarm indicates the specified chassis power supply failed.

Repetition

None

Event Codes

sonusConnexIpSystemAdminName
sonusConnexIpSystemServerName
sonusConnexIpSystemPowerSupplyId

Instance Fields

None

Action

Replace the power supply or source of power.

Refer to the respective hardware installation guide for power supply replacement procedures.

5000 Series HardwareInstalling SBC

Impact

The server is running without power supply redundancy. If the second power supply fails during this time, the server will go down.

Clearing

Automatic, sonusConnexIpSystemCEPowerSupplyNormalNotification