Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Add_workflow_for_techpubs
AUTH1UserResourceIdentifier{userKey=8a00a02355cd1c2f0155cd26c9b90306, userName='null'}
JIRAIDAUTHSBX-86216
REV5UserResourceIdentifier{userKey=8a00a02355cd1c2f0155cd26cd5909df, userName='null'}
REV6UserResourceIdentifier{userKey=8a00a02355cd1c2f0155cd26cb8305e9, userName='null'}
REV3UserResourceIdentifier{userKey=8a00a02355cd1c2f0155cd26c7cd0042, userName='null'}
REV1UserResourceIdentifier{userKey=8a00a02355cd1c2f0155cd26c99d02be, userName='null'}

The procedure to revert the 

Spacevars
0series4
application using the EMA is provided below. You can only revert the application for upgraded systems (offline or LSWU). You cannot revert a system to an older version after a server/system is ISO, or after installing the SBC software. The revert operation takes approximately 15 to 20 minutes to complete.


Revert Overview

Include Page
Clear_upgrade_directory_warning
Clear_upgrade_directory_warning

Any configurations performed after the upgrade are lost after the Revert operation. Once the revert completes, the configuration rolls back to the time stamp in the 'Last Used' field.

Once a revert is performed to a valid pre-6.0 SBC release, an upgrade to another pre-6.0 release is not supported. Upgrading to any other pre-6.0 releases requires the ConnexIP re-ISO installation. Refer to Re-Installing ConnexIP Operating System for SBC 5000 5400 Series or Re-Installing ConnexIP Operating System for SBC 7000 Series for more information on ConnexIP re-ISO installation.

Note
titleCaution

This procedure is service impacting.


Info
iconfalse
titleNote

The Revert procedure is not supported on the

Spacevars
0product
Spacevars
0model3
or
Spacevars
0product2
. If you require reverting these platforms to the previous version, perform an Application installation, and then a Configuration restore.


Info
titleNote

Beginning with 5.0 release, the Platform Manager is integrated into the EMA and hereafter referred to as EMA Platform Mode. So once it is reverted back to 3.x/4.x release, you can only use Platform Manager tool for subsequent upgrades.


Info
iconfalse
titleNote

The images depicted here are only for examples and do not indicate the latest build. Refer to the release notes for correct build versions.


Procedure

Perform this procedure to revert the 

Spacevars
0series4
application (after an upgrade) using the EMA.

  1. Call 
    Spacevars
    0company
     RTS/GPS to request a software upgrade status reset. 
  2. Launch the EMA (from either the active or standby server). Refer to Logging into EMA in Platform Mode for guidance.

  3. Navigate to Monitoring > Dashboard > System and Software Info to verify the versions.
    (An example screenshot is shown below. Your actual software version may vary).

    Caption
    0Figure
    1New Application and OS Version


  4. Navigate to Administration > System Administration screen.

    Caption
    0Figure
    1System Administration Screen


  5. Click Revert Software Version.
    The Revert Software Version screen displays the system or partition for the current version and the older version.

  6. Click to start the revert.
    A confirmation message appears on the screen informing you this action will change the boot software version to the previous release, plus warn you that this is a service-impacting action.
  7. Click Ok to proceed.

    Note
    titleCaution

    The Revert Software application simultaneously reverts both the Active and Standby server. Continuing the revert will reboot the upgraded server(s) to an earlier release. During this process, the browser session is lost necessitating logging back into the session.


    The Revert Software starts and changes the boot version to earlier version in both the active and standby server. For example, in this case, it is 06.02.00R000 version. You can see the revert status in the Log section.

    Caption
    0Figure
    1Revert Logs


    Caption
    0Figure
    1Continuing Revert Operation


  8. Once you see Rebooting message in the logs, log out from the EMA.

    Caption
    0Figure
    1Rebooting SBC Platform



Info
titleNote

The roles of Active and Standby server may switch between servers, depending on which boots first. In this case, WFDSBC01b completed the rebooting first and became active.

Pagebreak