Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Anchor
TopOfPage
TopOfPage

Include Page
SBXDOC101:_SBC 5100 5200 UnsupportedSBXDOC101:
_SBC 5100 5200 Unsupported

...

The

Spacevars
0company
 
Spacevars
0series
system is a 2U rack-mounted chassis. It can be front or center mounted in standard 19” wide racks, with options for 23” wide racks.

The SBC 5200/5100 chassis accommodates following modules:

...

The SBC 5210/5110 chassis accommodates following modules:

...

The following tasks are performed for physical replacement of a failed chassis with a new one:

...

:

...

...

Table of Contents
maxLevel3
minLevel3

...

Backup the Configuration

Before installing a new license file, a configuration backup must be taken by using the command saveConfig, which generates the .tar.gz backup file prior to the replacement.

...

  • 1x alarm port
  • 2x management port
  • 4x packet port
  • 2x high availability port
  • 1x BMC Serial Port
  • 1x BMC Field Service Port
  • 2x power

...


Image Removed 
Caption
0Figure
1Rear Panel LEDs for SBC 5x10 Series
 

...

  1. Connect the BMC and Management cables. For detailed information, see Plug the Cables Back section below. 
  2. Configure the BMC address.   
  3. Update the BMC Firmware. 
  4. Configure the Management port IP addresses. 

  5. Update the BIOS Firmware.

    For more information, see section SBC 5000 Series Chassis Replacement#Firmware Firmware Configuration and Upgrade.

    Note

    The data on your SSD drive can become corrupted if the BMC and BIOS versions do not correspond to the

    Spacevars
    0series
    version.


  6. Power off the chassis.

...

  1. Power off the chassis.
  2. Dismount the SSD drive from the new chassis.
  3. Push your SSD hard drive into the chassis.
  4. Screw in the screw holding the hard drive.
  5. After the 
    Spacevars
    0series
    is rack mounted and the drive is inserted, you must attach the front bezel to the 
    Spacevars
    0series
    by aligning 4 ball studs located on the bezel assembly to the ball stud sockets located on the 
    Spacevars
    0series
    chassis. Apply equal forward pressure to the four corners of the bezel assembly until each of the four corners “click-in”.
  6. Connect the power again. For detailed information, refer to the section SBC 5000 Series Chassis Replacement#Connecting Connecting to Power and Power on the Switch.

...

For details, refer to the section Upgrading SBC 5000 5400 Series Firmware.

Configure the MGMT IP Addresses

...

Info
titleNote:

Install/Upgrade any platform software and then install the application software on the replacement system. For details, refer to the section Installing SBC 5000 and 7000 Series Software.


Warning

An ISO (re-imaging) should be performed on every SBC received through Return Merchandise Authorization (RMA) process. To know more about re-installing ConnexIP OS, refer to:

...