The SBC, like other

Spacevars
0company
devices, uses SNMP traps to notify management applications of events. SNMP traps are the messages that notify a management client that an event has occurred on the SBC node. These traps are not displayed in EMA and can be viewed from Insight EMS or other SNMP manager configured as a trap target. In case of error scenario, a trap is initiated at the device and forwarded to the EMS or to the other SNMP manager for processing.

Note

Up to 32 trap targets can be configured on the SBC.


The supported SNMP trap types are SNMP v1, v2, and v3. These trap types can be configured. 

The following command is executed in CLI to configure the SNMP traps:

Code Block
% set oam snmp trapTarget myTarget ipAddress <ip address> state enabled 

Registering/Configuring Insight SNMP Network Management Station for SBC

Perform the following steps to register the

Spacevars
0product
 node:

  1. Log into the InsightTM Web-based Element Management System.

    Caption
    0Figure
    1EMS Screen

    Image Modified




  2. The Users & Roles window appears. Select Insight Administration from the Network Mgmnt roll-up (left hand side of the Users & Roles window).

    Caption
    0Figure
    1Register SBC EMS

    Image Modified




  3. The Insight Administration window appears. Select SBC 5x00 from the Register Node drop-down menu.

    Caption
    0Figure
    1SBC EMS Registration

    Image Modified


  4. Provide the name of the
    Spacevars
    0product
     in the Name field.
  5. Provide the Agent Login and Agent Password (default: admin/admin).
  6. Provide the information in Default IP Address for Host 1 and Host 2.
  7. Click Register.

Creating a View in EMA

Perform the following steps to create a view:

  1. Select Fault Manager from the Network Mgmnt roll-up (left hand side of the Users & Roles window). The Fault Manager window appears.

    Caption
    0Figure
    1View Creation

     Image Modified


  2. Select the Views tab.
  3. Select All from the Resource Groups drop-down menu.
  4. Select Create. The Create View option appears.
  5. Provide a view name in the View Name field.
  6. In the Bars option, select Create.

    Caption
    0Figure
    1Device selection for view creation

    Image Modified


  7. Select the devices from the Available Devices and place them in the Selected Devices option.
  8. Click OK. A view for the selected device will be created.
  9. Click Save. The view is saved and displayed in the left side pane.

    Caption
    0Figure
    1Saved View

     Image Modified


Viewing Traps

Perform the following steps to view the traps:

  1. Select Real-Time tab from the Fault Manager window.
  2. Select All from the Resource Groups drop-down menu.
  3. Select the view from the Views drop-down menu. Click Open. The view is displayed.

    Caption
    0Figure
    1View Traps

     Image Modified


  4. Double-click the Total Events bar. The Event Names appear for the selected device.

    Caption
    0Figure
    1Viewing Traps

     Image Modified


Clearing Traps

Perform the following steps to clear a trap:

  1. Select the trap to be cleared.

    Caption
    0Figure
    1Select alarm to clear

    Image Modified


  2. Select Clear from the Operations drop-down menu. The trap is cleared from the list.

    Caption
    0Figure
    1Cleared alarm

    Image Modified




SNMP Traps

The SBC supports following generic SNMP traps apart from the application specific traps or alarms:

  • authenticationFailure
  • coldStart
  • linkDown
  • linkUp

The traps are triggered under specific conditions:For detailed information about these traps, refer to the relevant Trap page using the links provided in the table below.

Caption
0Table
1Generic SNMP Trap Support


Generic SNMP TrapConditions
authenticationFailure - MINOR

When an SNMP request with mismatch of community name is received.

coldStart - INFORMATIONALWhen an SNMP entity has reinitialized itself and its configuration might have been altered.
linkDown - CRITICALWhen an SNMP entity detects that one of its communication links is down.
linkUp - INFORMATIONALWhen an SNMP entity detects that one of its lost communication links is reinstated
.For detailed information about these traps, refer to EMS Documentation
.