This section describes the dimensional, environmental, power, and network specifications and requirements for the Sonus SBC 2000 the 

Spacevars
0series2
System.

Dimensions and Weight

Equipment

Height mm/in.

Width mm/in.

Depth mm/in.

Weight lb./kg

Chassis with no interface cards or expansion modules

(1RU) - 44 mm / 1.75 in.

444 mm / 17.5 in.

534 mm / 21 in.

16.5 lbs / 7.48 kgs

Maximum supported configuration

(1RU) - 44 mm / 1.75 in.

444 mm / 17.5 in.

534 mm / 21 in.

23 lbs / 10.43 kgs

Environmental Ranges (Operation and Storage)

Environmental Parameter

Specification

Operating Environmental Conditions

Temperature: 5º to 40º Celsius
Humidity: 5% to 85% RH non-condensing
Altitude: 60 meters below sea level to 1800 meters above sea level

Storage Environmental Condition

Temperature: -40º to 70º Celsius

Cooling System

Internal forced convection

Power Supply

Multiexcerpt include
MultiExcerptName2000specs
nopaneltrue
PageWithExcerptSonus Ribbon SBC 1000-2000 System Power Supplies

For more information about the Sonus SBC 2000 the 

Spacevars
0company
power supply units, see Sonus Ribbon SBC 1000-2000 System Power Supplies.

Networking Interfaces

The Sonus SBC 2000

Spacevars
0series2
base configuration includes 5 Ethernet ports on the front panel of the unit.

  • 1 x 10/100/1000 Base-T administration port (used for initial setup)
  • 4 x 10/100/1000 Base-T ports

Ethernet Port Pinouts

The 10/100/1000 Base-T port pinouts are as follows:

...