Identify and download the correct firmware file for your platform type. The upgrade fails if the selected firmware upgrade file does not match the platform type. The following table identifies the correct firmware files for an upgrade:

Platform TypeFirmware file
SBC 5000 Series
(5100, 5110, 5200, 5210)

Upgrade

Paths

from 2.x to 3.x version:

  • bmc5X00_v3.xx.00-R000.rom
  • bmc5X00_v3.xx.00-R000.rom.md5sum

Upgrade from 3.x to 3.y version:

  • firmware-5XX0-V03.yy.00-R000.img
  • firmware-5XX0-V03.yy.00-R000.img.md5
SBC 5400

Upgrade from any version to latest version:

  • firmware-5400-V03.xx.00-R000.img
  • firmware-5400-V03.xx.00-R000.img.md5
SBC 7000 Series (Refer to Upgrading the BMC and BIOS Firmware for the procedure.)

Upgrade from any version to latest version:

  • firmware-7x00-V03.xx.00-R000.img
  • firmware-7x00-V03.xx.00-R000.img.md5

Upgrade Paths

There are two BMC firmware upgrade procedures based on the version from which you are upgrading. Each method requires a different file type as listed in the previous table. The SBC 5000 series supports both paths. The SBC 5400 supports only the upgrade method using the ".img" file.

The two BMC Firmware upgrade paths are listed below and identify which file type to use during the upgrade:

  • BMC upgrade from 2.x to 3.x: Use the ".rom" file. 
    For example: To upgrade from BMC 02.16.00 to 03.0017.00, use "bmc5X00_v3.017.0-R0.rom" file.

    note
    Info
    title
    Note

    The firmware upgrade to 3.x can only be done from version 02.16.00 or later. If the existing BMC version is older than 02.16.00, upgrade it to 02.16.00 using the standard method ".rom" file first and then perform an upgrade to 3.x version using  using a ".rom" file.


  • BMC upgrade from 3.x to 3.y OR 1.x to 3.y: Use the "Disc Image File.img" file. 

For example: To upgrade from BMC 03.00.00 to 03.

11

17.00, use "firmware-5XX0-V03.

11

17.00-R000.img" file.

Info
titleNote

Download the required BMC firmware version prior to continuing. Refer to Downloading Software from the Ribbon Support Portal for details.

Include Page
Screenshots_with_outdated_sw_fw_versions
Screenshots_with_outdated_sw_fw_versions

Upgrade BMC Firmware from Version 2.

x Version

X (SBC 5000 Series Only)

The following procedure describes how to upgrade the BMC firmware from 2.x to 3.x versions (02.16.00 to 03.00.00) version using the ".rom" file.

note

Download the required BMC firmware version to upgrade from Salesforce. To know more on how to download, refer to Downloading the Software from Salesforce.

Note

Use these steps only to upgrade BMC firmware from 02.16.00 to 03.00.00 version.

  1. Log on to the SBC BMC using the following credentials:
    Username: root
    Password: superuserGUI.

    Caption
    0Figure
    1BMC 2.16 Login Screen

    Image Modified

     
    The BMC Main screen is displayed. 

    Caption
    0Figure
    1BMC 2.16 Main Screen

     Image Modified


  2. Click Click Remote Control. The Remote Control window is displayed.  

    Caption
    0Figure
    1BMC 2.16 Remote Control
    screen
    Screen
     Image Modified



  3. Click Click Power Control in  in the Options panel. The Power Control and Status window is displayed. 

    Caption
    0Figure
    1BMC 2.16 Power Control
    screen
    Screen

    Image Modified 



  4. Choose Choose Power Off Server - Orderly Shutdown option. 

    Noteinfo

    The BMC Server server must be shutdown shut down prior to performing a firmware upgrade.


    Caption
    0Figure
    1BMC 2.16 BMC Orderly Shutdown
    Image Removed

    Image Added

     


  5. Click Click Perform Action. The BMC Server shuts down to initiate the shutdown process.

    Caption
    0Figure
    1BMC 2.16 BMC Shutdown
    Image Removed

    Image Added



  6. Click the Maintenance tab tab. The Maintenance window is displayed.

    Caption
    0Figure
    1BMC 2.16 Maintenance Window
    Image Removed

    Image Added



  7. Click Click Enter Update Mode. A message appears seeking your permission to proceed Confirm that you want to enter update mode when prompted.

    Caption
    0Figure
    1BMC 2.16 Maintenance Window Confirmation Message
    Image Removed

    Image Added



  8. Click Click OK to  to proceed. The BMC is now in the Upgrade Mode.

    Caption
    0Figure
    1BMC 2.16 Firmware Update window
    Image Removed

    Image Added



  9. Browse and select the firmware file to upload.

    Caption
    0Figure
    1BMC 2.16 Firmware File

    Image Removed

    Click Upload Firmware. The BMC validates the selected file The firmware file to upgrade from 2.x version should be a .rom file. For example: bmc5X00_v3.17.0-R0.rom file.

  10. Click Upload Firmware. The BMC validates the selected file.

    Info
    titleNote

    The BMC fails to upgrade if:

    • the selected version is same as the existing version.
    • the selected version is older than the existing version.
    • the selected firmware image is incorrect for the platform type. For example, selecting an SBC 5400 firmware file for an upgrade on the SBC 5000 Series platform.


    Once the verification is complete, a message is displayed stating the result of the verification.

    Caption
    0Figure
    1BMC 2.16 Firmware Validation
    Image Removed

    Image Added



  11. Click Click OK to  to proceed. The  The existing and the new BMC versions are displayed for validation.

    NoteThe BMC fails to upgrade if:

    - the selected version is same as the existing version.

    - the selected version is older than the existing version.

    Caption
    0Figure
    1BMC 2.16 Firmware Comparison

    Image Modified



  12. Click Click Start Upgrade to  to initiate the upgrade process.
    A confirmation message appears seeking your permission to proceed with the upgrade Confirm that you want to upgrade when prompted.

    Caption
    0Figure
    1BMC 2.16 Upgrade Confirmation message
    Image Removed

    Image Added

     


    Warning
    titleWarning

    Once the upgrade process starts, do not close the screen.- If

    • If the window is closed or connectivity is lost before the upgrade starts, re-login to BMC GUI and reboot BMC. The BMC takes approximately 10 minutes to boot. Once the BMC boots up, re-login to BMC GUI and restart the upgrade process from
    step1
    • step 1.
    - If
    • If the window is closed or the connectivity is lost during the upgrade process, wait for 20 minutes for the upgrade process to complete and try to access the BMC again. If you fail to gain access, contact
    the Sonus TAC team
    • Technical Support for assistance.


  13. Click Click OK to  to proceed. The BMC starts the firmware upgrade process.

    Caption
    0Figure
    1BMC 2.16 Upgrade Process
    Image Removed

    Image Added


    Once the upgrade process is complete, the BMC reboots and a message appears requesting you to open a new browser window to access the BMC GUI.

    Caption
    0Figure
    1BMC 2.16 Upgrade Process Complete
    Image Removed

    Image Added


  14. Exit the browser. 
  15. Clear the browser cache.
  16. Open a new browsing window to access the BMC GUI again.
  17. Access the same BMC IP address to reach the BMC login window. Observe the changes in the login window. In the new BMC version (033.00.00X), the login window has some includes additional browser settings displayed.

    Caption
    0Figure
    1BMC 3.
    0 New
    X Login Window
    Image Removed

    Image Added



  18. Log on to the SBC BMC using the following credentials:
    Username: root
    Password: superuser

    Caption
    0Figure
    1BMC 3.0 Main Screen

    Image Removed

    The look and feel of the new BMC version (03.00.00) is changed. Explore the new BMC GUI at your leisure.

Upgrade BMC Firmware from 3.x Version
  1. GUI.

Anchor
Upgrade BMC Firmware from 3.x Version for SBC 5400 and SBC 5000/7000 Series
Upgrade BMC Firmware from 3.x Version for SBC 5400 and SBC 5000/7000 Series
Upgrading BMC Firmware from Version 3.x or 1.x

The following procedure describes how to upgrade the BMC firmware from a 3.x version to a 3.x versions y version (for example; , from version 03.10.00 to version 03.1117.00) using the Disc Image Fileor from 1.x to a 3.x version using the ".img" file.

  1. Log on to the SBC BMC using the following credentials:
    Username: root
    Password: superuserGUI.

    Caption
    0Figure
    1BMC Login Screen

    Image RemovedImage Added

    The BMC main screen is displayed.

    Caption
    0Figure
    1SBC BMC Main Screen
    Image Removed

    Image Added


  2. Click Click Firmware Update.

    Caption
    0Figure
    1BMC Firmware Update option
    Image Removed

    Image Added


    The Firmware Update screen is displayed.

    Caption
    0Figure
    1BMC Firware Update screen
    Image Removed

    Image Added


  3. Click Click Browse, and from the Open dialog browse to and select select the firmware image (for example; firmware-5XX0-V<release>-V03.17.00-R000.img firmware image). Refer to the Warning table at the start of this page to make sure you have chosen the correct type of file for an upgrade. To  To determine the exact firmware version, see refer to the release notes in SBC Release Information for guidance.
    The chosen file displays next to the Browse button.

    Caption
    0Figure
    1Selected Firmware file

    Image Removed


     

  4. Click Upload.

    Info
    titleNote

    Click Upload.

    Note

    The firmware image is approximately 17MB file for the SBC 5000 Series and 24MB for the SBC 5400 and takes few minutes to upload based on the network.


    note
    Info
    title
    Note

    The BMC fails to upgrade if:- the

    • the selected version is same as the existing version.
    - the
    • the selected version is older than the existing version
    .
    • .
    • the selected firmware image is incorrect for the platform type. For example, selecting an SBC 5400 firmware file for an upgrade on the SBC 5000 Series platform.

     The The selected file is verified and the uploading process starts. Caption

    0Figure
    1Uploading Firmware file
    Image Removed


  5. Once the file verification is complete, BMC seeks your permission to proceed further , when prompted, click Confirm to proceed with the upgrade. Click Confirm to proceed.

    Note
    titleCaution

    This is a service-affecting procedure and will power off the host side of the SBC.

    Include Page
    _Host Shutdown Failure During BMC Upgrade
    _Host Shutdown Failure During BMC Upgrade

    Once the
    Caption
    0Figure
    1Firmware verification and confirmation window

    Image Removed

    Once upload starts, the actions performed are displayed in the same window along with the estimated time left to complete the process.

    Warning
    titleWarning

    Once the upgrade process starts, do not close the screen.- If

    • If the window is closed or connectivity is lost before the upgrade starts,
    re-login to
    • log back into BMC GUI and restart the upgrade process from
    step1
    • step 1.
    - If
    • If the window is closed or the connectivity is lost during the upgrade process, wait for 20 minutes for the upgrade process to complete and try to access the BMC again. If you fail to gain access, contact
    the Sonus TAC team for
    • Technical Support for assistance.
    caption


    0Figure
    1Firmware upload status

    Image Removed

    Once the update process is process is complete, a message is displayed stating the samecompletion message displays.

    Caption
    0Figure
    1Firmware Update Complete message
    Image Removed

    Image Added


  6. Click Click OK to  to complete the process.The BMC automatically restarts at this point.

  7. Close the existing browser window.

  8. Clear the browser cache and log on to the BMC GUI again. The updated BMC version is displayed on the BMC main screen.

note
  1. .

  2. Log onto the BMC GUI.

     The SBC BMC prompts you to change the password after a successful upgrade only if it is a default password.

    Info
    iconfalse
    titleNote

    This change is applicable only when the BMC is upgraded to version 03.16.00 and later versions. 


    Caption
    0Figure
    1Change Default Password Window

    Image Added


  3. Click OK to proceed. The User Management window is displayed.

    Info
    iconfalse
    titleNote

    You have an option to cancel the action. If canceled, the password remains the same as the default password and you are allowed to continue to work on BMC. However, the warning message is displayed again on your next login to BMC. This reminder continues until the password is changed. To know more about how to successfully change the SBC BMC password, refer to Changing the BMC Password


  4. Verify the upgraded version in the BMC main screen.

Continue to Upgrading SBC Application.