This section describes
hardware and software requirements and recommendations.To install and configure
, make sure the Virtual Machine (VM) host meets the following recommended hardware, server platform and software requirements....
...
|
The recommended hardware and software settings are intended to ensure optimum stability and performance. If the recommended settings are not used, system may not behave as expected. |
...
SBC SWe for KVM Hypervisor – Server Hardware Requirements
Multiexcerpt |
---|
MultiExcerptName | SBC SWe for KVM Hypervisor – Server Hardware Requirements |
---|
|
The following table lists the server hardware requirements. Caption |
---|
0 | Table |
---|
1 | KVM Hypervisor Server Hardware Requirements |
---|
| |
Configuration | Requirement |
---|
Processor | Intel Xeon processors (Nehalem micro-architecture or above) with 6 cores and above (processors should support hyper threading). |
|
...
| Ribbon recommends using Westmere (or newer) processors for better SRTP performance. These processors have the AES-NI instruction set for performing cryptographic operations in hardware. |
| RAM | Minimum 24 GB | Hard Disk | Minimum 500 GB | Network Interface Cards (NICs) | Minimum 4 NICs. |
|
...
| Make sure NIC has multi-queue support which enhances network performance by allowing RX and TX queues to scale with the number of CPUs on multi-processor systems. |
Info |
---|
| The Intel I350, x540, and 82599 Ethernet adapters are supported for configuring as SR-IOV and DirectPath I/O pass-through devices. |
| Ports | Number of ports allowed: - 1 Management port
- 1 HA port
- 2 Media ports
|
|
Warning |
---|
|
The software runs only on platforms using Intel processors. Platforms using AMD processors are not supported. |
...
...
BIOS Setting Recommendations
...
Ribbon recommends the following BIOS settings for optimum performance:
Caption |
---|
0 | Table |
---|
1 | Recommended BIOS Settings for Optimum Performance |
---|
|
BIOS Parameter | Recommended Setting | Details |
---|
Intel VT-x (Virtualization Technology) | Enabled | For hardware virtualization | Intel Hyper-Threading | Enabled | | Intel Turbo Boost | Enabled | | CPU power management | Maximum Performance |
|
...
For example, the BIOS settings are shown below for HP DL 380p Gen8 servers. For BIOS settings of other servers, refer to the respective vendor's website.
Caption |
---|
0 | Table |
---|
1 | BIOS Setting Recommendations for HP DL380p Gen8 Server |
---|
|
BIOS Parameter | Recommended Setting | Default Value |
---|
HP Power Profile | Maximum Performance | Balanced Power and Performance | Thermal Configuration | Maximum Cooling | Optimal Cooling | HW Prefetchers | Disabled | Enabled | Adjacent Sector Prefetcher | Disabled | Enabled | Processor Power and Utilization Monitoring | Disabled | Enabled | Memory Pre-Failure Notification | Disabled | Enabled | Memory Refresh Rate | 1x Refresh | 2x Refresh |
|
...
Multiexcerpt |
---|
MultiExcerptName | SBC SWe for KVM Hypervisor – Software Requirements |
---|
|
SBC SWe for KVM Hypervisor – Software RequirementsFollowing are KVM hypervisor and SBC SWe software requirements: Caption |
---|
| Software | Version | Tested or Qualified Version |
---|
|
|
...
|
---|
KVM Module | 3.10.0 or above | 3.10.0 | QEMU Emulator | 1.5.3 | 1.5.3 | libvirtd (libvirt) | 1.1.1 | 1.1.1 | virt-manager | 0.10.0 | 0.10.0 |
|
|
...
...
...
|
Processors and VM configuration (CPUs, RAMs, Virtual Hard Disk, NICs, and bridge Settings) must be identical for SBC SWe HA pair. |
...
|
BIOS settings and recommendations must not be changed once it is applied on the server. |
...
KVM Configuration Recommendations
...
Caption |
---|
0 | Table |
---|
1 | KVM Configuration Recommendations |
---|
|
vCPU | Minimum 4 vCPUs required. |
|
...
Any number of vCPUs may be configured depending upon the call capacity requirements, but the number should be even (4, 6, 8, etc.) to avoid impacting performance. |
|
KVM Direct-IO mode is only supported for PKT ports for vCPUs >=4.
vRAM | Reserve the memory based on call capacity and configuration requirements. Refer to for supported call capacities with different configuration limits. | Virtual Hard Disk | Set Hard Disk (virtual) size as 100 GB or more (based on requirements of retaining CDRs, logs, etc. for number of days). Note: Hard disk size cannot be changed after the SBC SWe software is installed. | vNICs | Set number of virtual NICs as 4 (1-MGMT, 1-HA, 1-PKT0 and 1-PKT1). - Use only Virt-IO driver.
- Associate each vNIC to separate bridges.
|
|
...
...
...
...
- KVM hypervisor version and VM configuration (vCPUs, vRAMs, Virtual Hard Disk, vNICs, and vSwitch Settings) must be identical for an SBC SWe HA pair.
|
...
...
- KVM hypervisor settings and recommendations must not be changed once it is applied on the server.
|
Multiexcerpt include |
---|
MultiExcerptName | _vlan_sriov_disable_dcb |
---|
PageWithExcerpt | _VLAN_SRIOV_Disable_DCB |
---|
|