Identify and download the correct firmware file for your platform type. The upgrade fails if the selected firmware upgrade file does not match the platform type. The following table identifies the correct firmware files for an upgrade:
Platform Type | Firmware file |
---|---|
SBC 5000 Series (5100, 5110, 5200, 5210) | Upgrade from 2.x to 3.x version:
Upgrade from 3.x to 3.y version:
|
SBC 5400 | Upgrade from any version to latest version:
|
SBC 7000 Series (Refer to Upgrading the BMC and BIOS Firmware for the procedure.) | Upgrade |
from any version to latest version:
|
There are two BMC firmware upgrade procedures based on the version from which you are upgrading. Each method requires a different file type as listed in the previous table. The SBC 5000 series supports both paths. The SBC 5400 supports only the upgrade method using the ".img
" file.
The two BMC Firmware upgrade paths are listed below and identify which file type to use during the upgrade:
BMC upgrade from 2.x to 3.x: Use the ".rom
" file.
For example: To upgrade from BMC 02.16.00 to 03.0017.00, use "bmc5X00_v3.017.0-R0.rom
" file.
Info | |
---|---|
| |
| |
The " |
Disc Image File
.img
" file. For example: To upgrade from BMC 03.00.00 to 03.
0417.00, use "firmware-5XX0-V03.
17.00-R000.img
" file.
Info | ||
---|---|---|
| ||
Download the required BMC firmware version prior to continuing. Refer to Downloading Software from the Ribbon Support Portal for details. |
Include Page | ||||
---|---|---|---|---|
|
The following procedure describes how to upgrade the BMC firmware from 2.x version using the ".rom
" file.
Log on to the SBC BMC GUI.
Caption | ||||
---|---|---|---|---|
| ||||
The BMC Main screen is displayed.
Caption | ||||
---|---|---|---|---|
| ||||
|
Click Remote Control. The Remote Control window is displayed.
Caption | ||||
---|---|---|---|---|
| ||||
Click Power Control in the
Options panel. The Power Control and Status window is displayed.
Caption | ||||
---|---|---|---|---|
| ||||
|
Choose Power Off Server - Orderly Shutdown option.
Info |
---|
The BMC server must be shut down prior to performing a firmware upgrade. |
Caption | ||||
---|---|---|---|---|
| ||||
Click Perform Action to initiate the shutdown process.
Caption | ||||
---|---|---|---|---|
| ||||
Click the Maintenance tab. The Maintenance window is displayed.
Caption | ||||
---|---|---|---|---|
| ||||
Click Enter Update Mode. Confirm that you want to enter update mode when prompted.
Caption | ||||
---|---|---|---|---|
| ||||
Click OK to proceed. The BMC is now in Upgrade Mode.
Caption | ||||
---|---|---|---|---|
| ||||
Browse and select the firmware file to upload. The firmware file to upgrade from 2.x version should be a .rom
file. For example: bmc5X00_v3.17.0-R0.rom
file.
Click Upload Firmware. The BMC validates the selected file.
Info | ||
---|---|---|
| ||
The BMC fails to upgrade if:
|
Once the verification is complete, a message is displayed stating the result of the verification.
Caption | ||||
---|---|---|---|---|
| ||||
Click OK to proceed. The existing and the new BMC versions are displayed for validation.
Caption | ||||
---|---|---|---|---|
| ||||
Click Start Upgrade to initiate the upgrade process. Confirm that you want to upgrade when prompted.
Caption | ||||
---|---|---|---|---|
| ||||
Warning | ||
---|---|---|
| ||
Once the upgrade process starts, do not close the screen.
|
Click OK to proceed. The BMC starts the firmware upgrade process.
Caption | ||||
---|---|---|---|---|
| ||||
Once the upgrade process is complete, the BMC reboots and a message appears requesting you to open a new browser window to access the BMC GUI.
Caption | ||||
---|---|---|---|---|
| ||||
Access the same BMC IP address to reach the BMC login window. In the new BMC version (3.X), the login window includes additional browser settings.
Caption | ||||
---|---|---|---|---|
| ||||
Log on to the SBC BMC GUI.
Anchor | ||||
---|---|---|---|---|
|
The following procedure describes how to upgrade the BMC firmware from a 3.x version to a 3.y version (for example, from version 03.10.00 to version 03.17.00) or from 1.x to a 3.x version using the ".img
" file.
Log on to the SBC BMC GUI.
Log on to the SBC BMC using the following credentials:
Username: root
Password: superuser
Caption | ||||
---|---|---|---|---|
| ||||
The BMC main screen is displayed.
Caption | ||||
---|---|---|---|---|
|
Click Click Firmware Update.
Caption | ||||
---|---|---|---|---|
|
The Firmware Update screen is displayed.
Caption | ||||
---|---|---|---|---|
|
Click Click Browse, and from the Open dialog browse to and select select the firmware image (for example; firmware-5XX0-V<release>-V03.17.00-R000.img firmware image). Refer to the Warning table at the start of this page to make sure you have chosen the correct type of file for an upgrade. To To determine the exact firmware version, see refer to the release notes in SBC Release Information for guidance.
The chosen file displays next to the Browse button.
Caption | ||||
---|---|---|---|---|
| ||||
Click Upload.
Info | ||
---|---|---|
|
Click Upload.
The firmware image is approximately 26MB file 17MB for the SBC 5000 Series and 24MB for the SBC 5400 and takes few minutes to upload based on the network. |
Info | ||
---|---|---|
| ||
The BMC fails to upgrade if:
|
The selected file is verified and the uploading process starts. Caption
0 | Figure |
---|---|
1 | Uploading Firmware file |
Once the file verification is complete, BMC seeks your permission to proceed further , when prompted, click Confirm to proceed with the upgrade. Click Confirm to proceed.
Note | ||
---|---|---|
| ||
This is a service-affecting procedure and will power off the host side of the SBC. |
Include Page | ||||
---|---|---|---|---|
|
Caption | ||||
---|---|---|---|---|
| ||||
Warning | ||
---|---|---|
| ||
Once the upgrade process starts, do not close the screen. |
0 | Figure |
---|---|
1 | Firmware upload status |
|
Once the update process is process is complete, a message is displayed stating the samecompletion message displays.
Caption | ||||
---|---|---|---|---|
|
Click Click OK to to complete the process.The BMC automatically restarts at this point.
Close the existing browser window.
Clear the browser cache and log on to the BMC GUI again. The updated BMC version is displayed on the BMC main screen.
.
Log onto the BMC GUI.
The SBC BMC prompts you to change the password after a successful upgrade only if it is a default password.
Info | ||||
---|---|---|---|---|
| ||||
This change is applicable only when the BMC is upgraded to version 03.16.00 and later versions. |
Caption | ||||
---|---|---|---|---|
| ||||
Click OK to proceed. The User Management window is displayed.
Info | ||||
---|---|---|---|---|
| ||||
You have an option to cancel the action. If canceled, the password remains the same as the default password and you are allowed to continue to work on BMC. However, the warning message is displayed again on your next login to BMC. This reminder continues until the password is changed. To know more about how to successfully change the SBC BMC password, refer to Changing the BMC Password. |
Info | ||||||
---|---|---|---|---|---|---|
| ||||||
For HA configuration, refer to Upgrade Flows for guidance | ||||||
For HA configuration, refer to Upgrade Flows for guidance. | ||||||
Noprint | ||||||
Panel | | |||||
|
Pagebreak |
---|