Accomplish the following steps to switch to GRHA mode:
Caption | ||||
---|---|---|---|---|
| ||||
Note |
---|
The services on standby SBC server must be stopped before switching to GRHA mode since the switch to GRHA mode causes a temporary HA link outage. The script will verify the state of the servers and make the necessary changes. |
From the CLI command prompt, perform one of the steps below, depending on your configuration. For example, in SBC Core, set bond monitoring type to network-connect
and leader election algorithm type to enhanced
:
Code Block |
---|
On the standby server, execute the following command:
Note |
---|
Bond monitoring is only applicable to SBC 5000/7000 series platforms. |
network-connect
and leader election algorithm type to enhanced
:Code Block | ||
---|---|---|
| ||
> request system admin sbx2 setHaConfig bondMonitoring network-connect leaderElection enhanced |
To set bond monitoring type to direct-connect
and retain currentValue
setting of leader election algorithm:
Code Block |
---|
> request system admin sbx2 setHaConfig bondMonitoring direct-connect leaderElection currentValue |
On the active server, execute the following command:
To set bond monitoring type tonetwork-connect
and leader election algorithm type to enhanced
:Code Block | ||
---|---|---|
| ||
> request system admin sbx1 setHaConfig bondMonitoring network-connect leaderElection enhanced |
To set bond monitoring type to direct-connect
and retain currentValue
setting of leader election algorithm:
Code Block |
---|
> request system admin sbx1 setHaConfig bondMonitoring direct-connect leaderElection currentValue |
0 | Figure |
---|---|
1 | Start SBC Application Panel |
Note |
---|
The standby server comes up and reconnects as standby with the GRHA mode enabled on both the machines. |
Accomplish the following step to verify GRHA mode:
Code Block | ||
---|---|---|
| ||
> show table system haConfig LEADER BOND SERVER NAME ELECTION MONITORING -------------------------------------------------- sbx1.eng.sonusnet.com enhanced network-connect sbx2.eng.sonusnet.com enhanced network-connect |
Accomplish the following steps to switch out of the GRHA mode:
Stop the standby SBC application. On the SBC main screen, navigate to Administration > System Administration > Platform Management. The Platform and SBC Application Controls window is displayed.To
stop the application, click Stop SBC Application in the status panel.Caption | ||||
---|---|---|---|---|
| ||||
Note |
---|
The services on standby SBC server must be stopped before switching out of the GRHA mode since the switch out of the GRHA mode causes a temporary HA link outage. The script will verify the state of the servers and make the necessary changes. |
set bond monitoring type to direct-connect
and leader election algorithm type to standard
Code Block |
---|
> request system admin sbx2 setHaConfig bondMonitoring direct-connect leaderElection standard |
On the active server, execute
, enter the following command:
To set bond monitoring type todirect-connect
and leader election algorithm type to standard
:Code Block |
---|
> request system admin sbx1 setHaConfig bondMonitoring direct-connect leaderElection standard |
Start the standby server. Log on to SBC application in EMA Platform Mode.
Caption | ||||
---|---|---|---|---|
| ||||
Note |
---|
The standby server comes up and reconnects as standby without the GRHA mode enabled on both the machines. |
Accomplish the following step to verify non-GRHA mode:
Code Block | ||
---|---|---|
| ||
> show table system haConfig LEADER BOND SERVER NAME ELECTION MONITORING -------------------------------------------------- sbx1.eng.sonusnet.com standard direct-connect sbx2.eng.sonusnet.com standard direct-connect |