Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Panel

In this section:

Table of Contents
maxLevel2

Warning

Spacevars
0company
Sonus-provided SFP modules must be used to guarantee proper operation of the external ports. Failure to follow this recommendation may cause permanent damage to the system.

...

  1. Attach an ESD wrist strap using the ESD grounding point on the rear panel of the chassis (see Connecting Electrostatic Discharge Wrist Strap for details).
  2. Disconnect the fiber optic and/or Cat 5 cables, as appropriate, from media ports (Media 0-4) and HA ports (HA 0-1).

  3. Disengage the SFP transceiver from

    Spacevars
    0series
    . The method used to disengage the SFP transceiver will vary according to the manufacturer. For example, hold the wire latch and move it downwards to the horizontal position and pull it outwards, as shown below.

    Note

    The 

    Spacevars
    0product
     
    Spacevars
    05200
     5200 chassis contains four media ports and the
    Spacevars
    0product
     
    Spacevars
    05100
     5100 chassis two media ports.

    Caption
    0Figure
    1Removing SFP

    Caption
    0Figure
    1Inserting SFP

  4. Insert the Sonus

    Spacevars
    0company
    -approved SFP transceiver into the desired socket and ensure that the latch mechanism engages.

  5. Reconnect the fiber optic and/or Cat 5 cables, as appropriate, to media and HA ports.
  6. Verify LEDs above the part are flashing indicating link status and data activity.
  7. Verify port functionality using the application.

...