Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Add_workflow_for_techpubs
AUTH2UserResourceIdentifier{userKey=8a00a02355cd1c2f0155cd26cb41059c, userName='null'}
AUTH1UserResourceIdentifier{userKey=8a00a0c85b2726c2015b58aa779d0003, userName='null'}
JIRAIDAUTHCHOR-3017
REV5UserResourceIdentifier{userKey=8a00a0c85b2726c2015b58aa779d0003, userName='null'}
REV6UserResourceIdentifier{userKey=8a00a0c85b2726c2015b58aa779d0003, userName='null'}
REV3UserResourceIdentifier{userKey=8a00a02355cd1c2f0155cd26cef30cd0, userName='null'}
REV1
 
UserResourceIdentifier{userKey=8a00a02355cd1c2f0155cd26c9d6032b, userName='null'}
REV2UserResourceIdentifier{userKey=8a00a0c86062358001607df6f45d0013, userName='null'}


Panel

Contents:

Table of Contents
maxLevel4



Info
iconfalse

Related articles:



Note

SWe Lite is not supported on Hypervisor platform VMWARE ESXi5.5 running on Dell PowerEdge 740 hardware.


Info

SWe Lite supports the following (depending on your license):

  • For Memory (RAM), valid settings are 1 GiB (1024 MiB), 1.5 GiB (1536 MiB), or 2.5 GiB (2560 MiB).
  • For vCPUs, valid settings are 1, 2, 4 or 10 vCPUs.

For detailed information, refer to SBC SWe Lite Hardware and Software Requirements.

For adding vCPUs or increasing memory on a SWe Lite upgraded to Release 8.0, refer to Adding vCPU and Increasing Memory/VM Size.


Multiexcerpt
MultiExcerptNameVMware

This section provides information on installing and running

Spacevars
0series3
on VMware

EXSi.

ESXi.

Prerequisites

Perform the steps in Downloading the SBC SWe Lite Package before performing this procedure.

 

Install SBC SWe Lite on the ESXi Server

note
Note
iconfalse
titleNote

A DHCP server is required to obtain a temporary address for the initial configuration. Also, two static IP addresses are required, one IP address each for the management port and media port.

Screen captures in on this section page show fields and values that represent a typical installation. When prompted, use values and responses appropriate for your location. 


Warning
iconfalse
titleWarning

Spacevars
0series3
is a closed network device. Customer modifications at the Linux level are not allowed or supported. These modifications can cause stability, update and fail-over issues.

Customers should only configure

Spacevars
0series3
using the supported interfaces (WebUI, CLI, REST, EMA, and EMS).


Note

Install vSphere

 If there is a need to access the ESXi server remotely, download and install vSphere Client to the desktop.

From the VMware ESXi Welcome page, click Download vSphere Client for Windows.
Caption
0Figure
1Download vSphere Client
3Download vSphere Client

Image Removed

  • After installing, login to the vSphere Client using the appropriate login credentials.

    Caption
    0Figure
    1Logon to VMware vSphere
    3Logon to VMware vSphere

    Image Removed

  • Identify and reserve two static IP addresses prior to creating the virtual

    Spacevars
    0series3
    .

    Note
    iconfalse
    titleNote

    One IP address each is required for the management port and media port. In the examples below, the management port is on the 10.56.230.x subnet and the media port is on the 10.56.227.x subnet.

  • titleSBC SWe Lite Operations in an ESXi Cluster are Supported, with Restrictions


    The SBC SWe Lite supports operations within an ESXi host under the control of a vCenter Server (centralized management utility for VMware) provided the operations and features invoked on the ESXi host by the vCenter Server match those invoked by the ESXi host console when running outside the control of the vCenter Server.

    Refer to the following guidelines and restrictions:

    1. Select operations on the ESXi host initiated by the vCenter Server (such as those not available with the ESXi host console when running in standalone mode) may result in a disruption of SBC SWe Lite operations. Examples of popular vCenter Server-initiated operations that are not supported by the SBC SWe Lite include vMotion and Fault Tolerance.
    2. If unsupported vCenter Server-initiated operations result in a disruption of the SBC SWe Lite, a new unprovisioned (blank) and unlicensed SBC SWe Lite may need to instantiated to replace the original SBC SWe Lite instance.  Please contact Ribbon TAC to initiate a licence re-issuance.
    1. Use VMware vSphere Client to connect to the ESXi server.
    2. Enter the ESXi server IP address into a browser address bar to login.

    3. After logging on to the ESXi server, select Deploy OVF Template from the File drop-down list.

    4. Select the location of the OVF package, and then click 

    Install SBC SWe Lite on the ESXi Server

    1. Log on to the ESXi server.

      Caption
      0Figure
      1ESXi IP Address
      3ESXi IP Address

      Image Removed

    2. After landing on the ESXi server, select Deploy OVF Template from the File drop-down menu.

      Caption
      0Figure
      1Deploying OVF Template
      3Deploying OVF Template

      Image Removed

    3. Select the location of the OVF package, and then click Next.

      Caption
      0Figure
      1OVF Template Location
      3OVF Template Location
      Image Added


    4. When the OVF Template Details pane opens, make

      Image Removed

      The OVF Template Details screen displays. Make note of the information listed and then click click Next.

      Caption
      0Figure
      1OVF Template Details
      3OVF Template Details
      Image Removed

      Image Added


    5. The When the Name and Location screen displays. Rename the  pane opens, rename the 

      Spacevars
      0series3
       instance to make it unique in the inventory folder, and then click click Next.

      Caption
      0Figure
      1Rename the File
      3Rename the File

      Image Modified


    6. Select the the Resource Pool to  to deploy the template, and then click click Next.

      Caption
      0Figure
      1Select Resource Pool
      3Select Resource Pool
      Image Removed

      Image Added


    7. Ensure the that the Thick Provision Lazy Zeroed option  option is selected on the in the Disk Format screen dialog box, and click then click Next.

      Caption
      0Figure
      1Disk Format
      3Disk Format
      Image Removed

      Image Added


    8. On the Review the Network Mapping screen, if required,  dialog box. If necessary, select a different media port network interface from the the Destination Networks drop drop-down menulist, and click then click Next.

      Caption
      0Figure
      1Network Mapping
      3Network Mapping
      Image Removed

      Image Added


    9. Make note of the deployment settings, and then click click Finish to create the

      Spacevars
      0series3
       to start the deployment task.

      Caption
      0Figure
      1Ready to Complete
      3Ready to Complete
      Image Removed

      Image Added

       

       


    Info

    Ribbon recommends that all customers review and, if necessary, optimize their Network Interface configurations before proceeding. Failure to do so could lead to interface mapping issues. See Mapping Network Interfaces and then return to this section

    Note
    titleConfigure Interface Mapping

    If you do not have the necessary permissions to configure interface mapping using the GUI, refer to Mapping Network Interfaces for CLI instructions.

    Edit the Virtual Machine Settings

    1. Select the newly-created 

      Spacevars
      0series3
       from the list in the left pane.

    2. Select the the Edit virtual machine settings link  link on the the Getting Started tab tab.
    Note
    iconfalse
    titleNote

    The default

    Spacevars
    0series3
    comes with

    512 MB

    1 GiB memory, one CPU and five network interfaces.  

    Configuring Virtual Network Adapters

    1. Select Network adapter 1 from the Hardware tab of Virtual Machine Properties.
    2. In MAC Address section of the right window pane, select Manual

    3.  

      Caption
      0Figure
      1Edit Virtual Machine Settings
      3Edit Virtual Machine Settings

      Image Removed

    4. From the Hardware tab, select Memory from the left panel.
    5. From the Memory Configuration panel, modify the memory size if required by clicking the arrows in the Memory Size field and click OK.

      Note
      iconfalse
      titleNote

       The default memory size is 512 MB. Memory size can be increased to 1GB if desired, but it is not required.

      Caption
      0Figure
      1Set Memory Size
      3Set Memory Size

      Image Removed

    6. Power on the

      Spacevars
      0series3
       by selecting Power on the virtual machine on the Getting Started tab.
      Caption
      0Figure
      1Power on Virtual Machine
      3Power on Virtual Machine

      Image Removed

    7. Click the Console tab, and wait for the login prompt (press enter a few times if nothing appears).

    8. Once the login prompt shows a valid fingerprint number, select the Getting Started tab.
    9. Click Power off the virtual machine.

    10. You must assign the MAC address manually. Do not accept the automatic default.
      The MAC address field is populated with the first three octets.


    11. Finish configuring the static MAC address provided by your Network IT Administrator.

    12. Repeat for the remaining four Network adapters (2 -5).

      Click Edit virtual machine settings.
      Caption
      0Figure
      1
      Basic Tasks3Basic Tasks

      Image Removed

    13. Select Network adapter 1 from the Hardware tab of Virtual Machine Properties.

    14. Make note of the MAC Address and Network Connection as shown below.

      Note
      iconfalse
      titleNote

       The MAC address and network mapping information for all five Network adapters is required for further configuration from the console.

      Caption
      0Figure
      1MAC Address and Network Connection Data
      3MAC Address and Network Connection Data

      Image Removed

    15. Repeat steps 9-10 for Network adapter 2 through Network adapter 5.
    16. Configure Network Adapter 1


      Image Added


    17. Configure at least two network interfaces for the appropriate network.

    18. Click OK to save and then exit the Settings window.

    19. Power on the 

      Spacevars
      0series3
       by selecting Power on the virtual machine link on Select Power on the virtual machine from the Getting Started tab.

      Caption
      0Figure
      1Power on Virtual Machine
      3Power on Virtual Machine

      Image Added


    20. Click the Console tab.Image Removed


    Complete Initial Setup

    1. Enter the initial Admin IP address of the
      Spacevars
      0series3
      into a web browser.
    2. Verify/change information on the Initial Sonus SBC Setup window as required, and click OK.

      Caption
      0Figure
      1Initial Sonus SBC Setup
      3Initial Sonus SBC Setup

      Image Removed

      Note
      iconfalse
      titleNote

       After completion of the previous step, the VM automatically reboots, and after the reboot is complete the

      Spacevars
      0series3
      is ready for use.

    Proceed to SBC SWe Lite Initial Setup. After setup is complete, proceed to License Installation.

    License Installation

    Trial License Installation

    If you are installing an SBC SWe Lite for a trial or demonstration deployment, proceed to Obtaining and Installing a Permanent SWe Lite Trial License.

    Production License Installation

     
    If you are installing an SBC SWe Lite instance to carry live enterprise traffic, proceed to Obtaining and Installing a SWe Lite License.


    Pagebreak