Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
CSS Stylesheet
h1, h2, {font-size: 18pt !important;}
h3 {font-size: 16pt !important;}
h4 {font-size: 14pt !important;}
h5 {font-size: 14pt !important;}

...

Noprint
Panel
borderColorgreen
bgColortransparent
borderWidth2

Back to Administration and Maintenance

Table of Contents

...

Panel

In this section:

Table of Contents
maxLevel3

Pagebreak

How to Use This Guide

This guide lists the minimum number of tasks recommended to maintain an in-service 

Spacevars
0series5
system. This guide is not intended to explain diagnostics, repair specific faults, nor is it intended to optimize performance. File locations and system settings may vary, mainly due to customer-specific configurations and requirements.

Warning
titleWarning
Some procedures in this guide will interrupt/halt/prevent call processing and/or call accounting data collection. Do not perform any procedure if you do not know or understand the implications of performing that procedure.

This guide does not cover the following topics. Refer to the specified documents for more information on them.

  • Troubleshooting—When the system generates alarms or traps indicating trouble, see the SBC Core Alarms

...

 

Info

As a routine maintenance best practice,

Spacevars
0company
recommends the following:

(tick)  Build a template and create a daily/weekly record log, spreadsheet, or database that you can use to record the observed results and notes.

(tick)  Identify what tasks in the Routine Maintenance Guide you intend to run and set a schedule. Include fields against each task such as run date, run time, results, and comments.

(tick)  Plan your day to run the checks. If a day or task is omitted, make sure you annotate that the task was not run.

(tick)  Look for trends.

(tick)  If there is an anomaly in a result, pass the event or incident on for triage. Contact Customer Support.

...

 

...

Back to Top

SBC Access Methods

See How to Access the SBC for guidance with accessing the SBC EMA, EMA (Platform Mode), CLI, and BMC interfaces.

Pagebreak

Anchor
RoutineDailyMaintenance
RoutineDailyMaintenance
Routine Daily Maintenance

Routine

Spacevars
0product
daily maintenance tasks include the following activities:

Backing Up SBC Configuration

This section includes the following methods for backing up the 

Spacevars
0product
configuration:

Info
titleNote
Telecommunications laws may require that call records be stored for a specific amount of time both on and off site. Check for compliance.

Anchor
BackUpSBCConfigurationUsingEMA
BackUpSBCConfigurationUsingEMA
Back Up SBC Configuration Using EMA

Perform the following procedure to back up the current configuration using EMA:

  1. Backup your configuration using the procedure on the page System Administration - Backup

...

  1. and Restore.
  2. Copy your configuration to a remote location using the procedure on the page System Administration - Backup

...

  1. and Restore.

Anchor
BackUpSBCConfigurationUsingCLI
BackUpSBCConfigurationUsingCLI
Back Up SBC Configuration Using CLI

Perform the following procedure to back up the current configuration with the CLI:

  1. From the top-level CLI mode, enter the command:

    Code Block
    languagenone
    request system admin <SBC_system_name> saveConfig fileNameSuffix <filename.suffix> 
  2. When prompted to continue, enter 'yes'.  A message displays indicating the configuration was saved to a tar.gz file.
  3. Copy the latest <filename>.tar.gz file from the /var/log/sonus/sbx/config directory to a remote location using FileZilla or some other software utility.

...


 

Info
titleNote

...

The SBC stores up to 10 manual and 7 automatic backup files.


Pagebreak

Monitoring SBC Status

This section includes the following methods for monitoring

Spacevars
0product
various status indications:

Anchor
MonitorEMAAlarms
MonitorEMAAlarms
Monitoring EMA Alarms

To monitor outstanding alarms across all managed objects from the EMA, see Dashboard - Alarms page.

Anchor
MonitorSystemStatusFromEMA
MonitorSystemStatusFromEMA
Monitoring System Status From EMA

To monitor the status of the following entities from the EMA, see Dashboard - System Status page.

  • Server Status—status of the system including the name, hardware and software versions system up-time.
  • Fan Status—current fan speeds.
  • Hard Disk Status—hardware information about the on-board disks along with total capacity and status.
  • Hard Disk Usage—disk status and usage.
  • Power Supply Status—status of the power supply including any failures.
  • Daughter Board Status—list of daughter boards present on the system.
  • Policy Server Status—statistics of the routing database and application (local or external).

Anchor
MonitorStatusFromCLI
MonitorStatusFromCLI
Monitoring Status From CLI

To monitor system status from CLI top-level mode, the following commands are available. For additional commands and command details, see  Show Status System  and Show Table System pages.

Code Block
languagenone
show status global callCountStatus all
show status system daughterBoardStatus
show status system ethernetPort mgmtPortStatus / packetPortStatus
show status system fanStatus
show status system hardDiskStatus
show status system hardDiskUsage
show status system powerSupplyStatus
show status system serverStatus
show status system syncStatus
show status system systemCongestionStatus

...

 

Pagebreak

Monitoring SBC Performance

Use one or more of the following methods below to monitor

Spacevars
0product
performance.

Anchor
MonitorPerformanceFromEMA
MonitorPerformanceFromEMA
Monitoring Performance From EMA

  • Call Count Statistics
  • TCP General Group Statistics
  • UDP General Group Statistics
  • System Congestion Statistics
  • DSP Call Statistics
  • DSP Usage Statistics
  • DSP Utilization

To monitor the following statistics from the EMA (Platform Mode), see Monitoring - Dashboard page.

  • Alarms
  • CAC Offenders Status
  • CPU
  • Disk Usage
  • Hardware Inventory
  • IP Interface Status
  • Live Monitor
  • Memory Usage
  • Ports
  • System Statistics
  • System Status
  • System and Software Info
  • Task Usage

Anchor
MonitorPerformanceFromCLI
MonitorPerformanceFromCLI
Monitoring Performance From CLI

To monitor

Spacevars
0product
performance data from CLI top-level mode, the following commands are available. For additional commands and command details, see Show Status Command Details - CLI and Show Table System pages.

Code Block
languagenone
show status alarms historyStatus
show status system dspRes dspCallCurrentStatistics
show status system dspRes dspUsageCurrentStatistics
show status global tcpGeneralGroupStatistics
show status system dspStatus dspUsage
show status system ethernetPort mgmtStatistics
show status system ethernetPort packetStatistics
show status system systemCongestionCurrentStatistics
show status global udpGeneralGroupStatistics

...

 

Pagebreak

Anchor
RoutineWeeklyMaintenance
RoutineWeeklyMaintenance
Routine Weekly Maintenance

Perform the following

Spacevars
0product
routine maintenance tasks on a weekly basis:

General Maintenance

  • Wipe the outer case clean with a slightly moist (not wet), lint-free cloth.
  • Inspect air filters, and clean or replace if needed. To replace an air filter, see the applicable page:
  • Check external fan covers or grills for excessive dust buildup or obstructions; clean, if necessary, by gently wiping with a clean, lint-free cloth, making sure not to penetrate the protective cover or grill.
  • Check fans to ensure they are operating and not generating any unusual noises. Make certain the fan is operating by holding your hand next to the intake vent to be sure air is flowing into the unit. If a fan is not running or unusual noises are present, contact Customer Support.

Backing Up SBC Logs

The Logs Management window (EMA

...

- Platform Mode)

...

allows you to manage the following logs. For details,

...

...

.

  • Core Dumps
  • Event Logs
  • Message Logs
  • System Dump
  • Back Trace
  • Apache
  • Netconf
  • User Activity
  • Install Logs
  • Upgrade Logs

...

Include Page
Netconf_security_protection
Netconf_security_protection

Info
titleNote

The TShark Logs and System Diagnostic Logs are available only when you select and execute these objects, for more information on usage of these objects, refer to the respective links Troubleshooting Tools - TShark and System Administration - System Diagnostics.

 

Deleting Old SBC Logs

Delete unneeded files, such as old core dump files, on a regular basis. To manage and remove log files from the EMA (Platform Mode), see Log Management page.

Viewing SBC Log Files and Status From CLI

To view the configured parameters for all SBC event types from the CLI, use the command:

Code Block
languagenone
show configuration oam eventLog typeAdmin

To view the event log status for all event types, use the command:

Code Block
languagenone
show status oam eventLog typeStatus 

...

 

...

Back to Top

Pagebreak

Anchor
SBCUpgradeGuidelines
SBCUpgradeGuidelines
SBC Upgrade Guidelines

Perform the following activities prior to upgrading the

Spacevars
0product
:

Preparation

Perform pre-upgrade checks and system baselining, plus gather any requisite upgrade information.

  1. Read all release notes for any pertinent upgrade instructions

...

  1. , applicable patches and announcements. See Production Releases page for available release notes.

...

Read all applicable WBAs (Check the associated release notes for applicable WBAs).

Tip

To view WBA details, login to Customer Portal and from left panel, enter WBA into the Find Solutions search field, then click Go

  1. Download the software in advance.

  2. Verify network is healthy and in a condition to accept an upgrade.
  3. Familiarize yourself with the upgrade and roll-back procedures.
  4. Select a period of low traffic to perform the upgrade. Inform end users.
  5. Contact Customer Support to schedule on-call support.

Backup

Back-up the system in the unlikely event that a rollback.is required.

Upgrade

Spacevars
0series5
upgrade procedures. Refer to  Upgrading SBC Application page and the latest release notes from Production Releases page for upgrade details.

Decision Point

Execute your tests to verify the system is fully operational.

  1. Ensure the upgraded software release and data migration has no detrimental impact on existing functionality.
  2. Test interoperability with existing third-party applications, OSS, OA&M, BSS, and so on.
  3. Focus on customer-sensitive aspects.

Failure Recovery

If problems are detected that cannot be resolved, consider backing out of the software update.

Post-Upgrade Monitoring

Verify following:
1. No new fault/alarm conditions
2. No errors in system logs
3. No call failure ratio increases (for example, decreased ASR)

Commit Software

...

...

...

Back to Top

Pagebreak

Anchor
ShutdownandStartupProcedures
ShutdownandStartupProcedures
Shutdown and Startup Procedures

The following procedures are included in this section:

Anchor
PowerOff
PowerOff
Powering Off the SBC

To power off the

Spacevars
0product
, perform the following steps:

  1. Enter the BMC management IP address into a web browser.
  2. Login to the BMC as user root.
  3. Click the Remote Control tab to open the Remote Control screen.

    Caption
    0Figure
    1Remote Control Tab

    Image Modified

  4. Click Power Control (or click Server Power Control from the left tree menu) to open the "Power Control and Status" screen.

    Caption
    0Figure
    1Select "Power Control" Button

    Image Modified



  5. Select Power Off Server - Orderly Shutdown option and click Perform Action.

    Caption
    0Figure
    1Choose Orderly Shutdown
    Image Modified
Noprint

Back to Shutdown and Startup Procedures

Anchor
PowerOn
PowerOn
Powering On the SBC

To power on the

Spacevars
0product
, perform the following steps:

  1. Enter the BMC management IP address into a web browser.
  2. Login to the BMC as user root.
  3. Click the Remote Control tab to open the Remote Control screen.
  4. Click Power Control (or click Server Power Control from the left tree menu) to open the "Power Control and Status" screen (see screenshot above for example).
  5. Select Power On Server option and click Perform Action.

    Caption
    0Figure
    1Choose option to Power On Server

    Image Modified

Noprint

Back to Shutdown and Startup Procedures

Anchor
StopStart
StopStart
Stopping/Starting/Restarting/ Rebooting the SBC

Stop the SBC Application

To stop the SBC Application, perform the following steps:

  1. Login to the EMA (Platform Mode) and navigate to Administration > System Administration > Platform Management.
    The Platform and SBC Application Controls window appears.

  2. Click Stop SBC Application.

Start the SBC Application

To start the SBC Application, perform the following steps:

  1. Login to the EMA (Platform Mode) and navigate to Administration > System Administration > Platform Management.
    The Platform and SBC Application Controls window appears.

  2. Click Start SBC Application.

Restart the SBC Application

To restart the SBC Application, perform the following steps:

  1. Login to the EMA (Platform Mode) and navigate to Administration > System Administration > Platform Management.
    The Platform and SBC Application Controls window appears.

  2. Click Restart SBC Application.

Reboot the SBC Application

To reboot the SBC Application, perform the following steps:

  1. Login to the EMA (Platform Mode) and navigate to Administration > System Administration > Platform Management.
    The Platform and SBC Application Controls window appears.

  2. Click Reboot Platform.

For detailed information on different SBC application, refer to System Administration - Platform Management.

Monitor the Platform and SBC Application Controls window to observe the various processes.

Caption
0Figure
1Platform and SBC Application Controls window

Image Modified

Noprint

Back to Shutdown and Startup Procedures

...

Pagebreak