Panel | ||||
---|---|---|---|---|
In this section:
|
Warning | ||
---|---|---|
| ||
'VLANs are not supported on SR-IOV PKT interfaces. |
Info | ||
---|---|---|
| ||
Ensure that SR-IOV is enabled on the BIOS settings of the host by logging in through iLO console. |
Info | ||
---|---|---|
| ||
SR- IOV is a licensed feature on the VMware and the "VMware vSphere Enterprise Plus" license must be procured to enable SR-IOV Support on the ESXi. |
Install SR-IOV supported two 10 Gigabit PCI cards.
One virtual interface for Management Port
One virtual interface for HA Port
Two virtual interfaces for SR-IOV Ports
Info | ||
---|---|---|
| ||
It is recommended to configure all four ports with different IP addresses in four different networks. For example:
|
Perform the following steps:
Log on to VMware ESXi GUI as the root user.
Caption | ||||
---|---|---|---|---|
| ||||
Include Page | ||||
---|---|---|---|---|
|
To check the status of the SR-IOV cards:
Navigate to Host > Manage.
Select the tab Hardware.
Ensure both the SR-IOV cards are in disabled state or the Passthrough must be in disabled state.
Caption | ||||
---|---|---|---|---|
| ||||
If the SR-IOV cards are not disabled, they must be disabled by performing following:
Enable SSH. To enable SSH,
Navigate to Host and select the tab Actions.
From the drop-down list, select the option Services. Click Enable Secure Shell (SSH) and Enable console shell.
Caption | ||||
---|---|---|---|---|
| ||||
Check the name of the NIC cards. To check the name of the NIC cards,
Log on to CLI as root.
Execute the following command:
Code Block | ||
---|---|---|
| ||
lspci|grep X540 |
The following is the sample display output:
Code Block |
---|
0000:0b:00.0 Network controller: Intel(R) Ethernet Controller X540-AT2 [vmnic8] 0000:0b:00.1 Network controller: Intel(R) Ethernet Controller X540-AT2 [vmnic9] |
Open the esx.conf
file and find the PCI ID associated with the NIC card.
Change the owner of the PCI ID from passthrough
to vmkernel
.
Execute the following command:
Code Block |
---|
vi /etc/vmware/esx.conf |
The following is the sample display output:
Code Block |
---|
/system/uuid = "5a33649d-c9db-e792-c676-5cb9018acc24" /system/uservars/psa/defaultLunMasksInstalled = "1" /system/uservars/corestorage/Filter/DefaultVMWRulesLoaded = "1" /system/uservars/corestorage/VAAI/DefaultVMWRulesLoaded = "1" /system/uservars/host-acceptance-level = "partner" /resourceGroups/version = "6.5.0" /adv/Misc/HostIPAddr = "10.54.12.81" /adv/Misc/DiskDumpSlotSize = "2560" /adv/Misc/HostName = "hpg9-9" /adv/Net/ManagementIface = "vmk0" /adv/Net/ManagementAddr = "10.54.12.81" /adv/UserMem/UserMemASRandomSeed = "1418738923" /adv/UserVars/HostClientCEIPOptIn = "1" /device/00000:005:00.0/vmkname = "vmhba1" /device/00000:002:00.0/vmkname = "vmnic0" /device/00000:002:00.2/vmkname = "vmnic2" /device/00000:003:00.0/vmkname = "vmhba0" /device/00000:002:00.1/vmkname = "vmnic1" /device/00000:011:00.1/owner = "vmkernel" /device/00000:011:00.1/device = "1528" /device/00000:011:00.1/vendor = "8086" /device/00000:011:00.1/vmkname = "vmnic9" /device/00000:004:00.2/vmkname = "vmnic6" /device/00000:004:00.1/vmkname = "vmnic5" /device/00000:002:00.3/vmkname = "vmnic3" /device/00000:004:00.0/vmkname = "vmnic4" /device/00000:005:00.1/vmkname = "vmhba2" /device/00000:004:00.3/vmkname = "vmnic7" /device/00000:011:00.0/vmkname = "vmnic8" /device/00000:011:00.0/vendor = "8086" /device/00000:011:00.0/device = "1528" /device/00000:011:00.0/owner = "vmkernel" - /etc/vmware/esx.conf 33/499 6% |
Save the file.
Reboot the host.
In the VMware ESXi GUI, navigate to Host > Manage.
Select the Hardware tab.
From the PCI Devices, select the SR-IOV card.
Caption | ||||
---|---|---|---|---|
| ||||
Click Configure SR-IOV.
The window to configure the SR-IOV card is displayed.
For the option Enabled, select Yes and set the number of virtual functions.
Caption | ||||
---|---|---|---|---|
| ||||
Click Save.
Configure the other SR-IOV card. Repeat the steps from 4 to 6.
Reboot the host by clicking Reboot host.
Caption | ||||
---|---|---|---|---|
| ||||
Caption | ||||
---|---|---|---|---|
| ||||
Click Reboot.
The VMware ESXi login window is displayed with the message "The host is rebooting...".
Caption | ||||
---|---|---|---|---|
| ||||
Once the virtual function is created, the SR-IOV cards and the Passthrough for the virtual functions display the status as "Active".
Caption | ||||
---|---|---|---|---|
| ||||
Perform the following steps:
Navigate to Networking. From the Port group tab, click the Add port group.
The Add port group window is displayed.
Caption | ||||
---|---|---|---|---|
| ||||
Include Page | ||||
---|---|---|---|---|
|
Caption | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
| ||||||||||
|
Perform the following steps:
Navigate to Networking. From the Port group tab, click the Add port group.
The Add port group window is displayed.
Caption | ||||
---|---|---|---|---|
| ||||
Include Page | ||||
---|---|---|---|---|
|
Caption | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
| ||||||||||
|
Perform the following steps:
Navigate to Virtual Machines. Click Create / Register VM to create or register a virtual machine. The Select creation type option is displayed.
Caption | ||||
---|---|---|---|---|
| ||||
Include Page | ||||
---|---|---|---|---|
|
Select the option Create a new virtual machine.
Click Next.
The Select a name and guest OS option is displayed.
Caption | ||||
---|---|---|---|---|
| ||||
Caption | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
| ||||||||||
|
Click Next.
The Select storage option is displayed.
Select datastore1.
Info | ||
---|---|---|
| ||
Ensure that the datastore has minimum 500 GB or more space. This datastore is required to store all log-related data files. |
Caption | ||||
---|---|---|---|---|
| ||||
Click Next.
The Customize settings option is displayed.
Configure virtual hardware from Customize settings:
Setting CPU
When configuring virtual CPUs within the vSphere Web Client, you can configure:
The following table provides the examples of socket determination based on the CPU and Cores per Socket within the vSphere Web Client:
Caption | ||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ||||||||||||||||||||||||
|
Info | ||
---|---|---|
| ||
A minimum of 4 vCPUs is required. Any number of vCPUs may be configured depending upon the call capacity requirements, but the number should be even (4, 6, 8, etc.) to avoid impacting performance.
|
Caption | ||||
---|---|---|---|---|
| ||||
Caption | ||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ||||||||||||||||||||
|
Setting Memory
Caption | ||||
---|---|---|---|---|
| ||||
Caption | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
| ||||||||||||
|
Setting Hard disk 1
Caption | ||||
---|---|---|---|---|
| ||||
Caption | ||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ||||||||||||||||||||
|
Setting SCSI Controller
Caption | ||||
---|---|---|---|---|
| ||||
Caption | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
| ||||||||||
|
Setting Network Adapter 1
The Network Adapter 1 is used for provisioning MGMT ports.
Caption | ||||
---|---|---|---|---|
| ||||
Caption | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
| ||||||||||
|
Select Add network adapter. The option to create New Network Adapter for HA port is displayed.
Caption | ||||
---|---|---|---|---|
| ||||
Caption | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
| ||||||||||
|
Click Add other device to continue the configuration on PKT0 and PKT1.
Caption | ||||
---|---|---|---|---|
| ||||
Select the option PCI device from the drop-down list.
Caption | ||||
---|---|---|---|---|
| ||||
Repeat steps g and h to create one more PCI Device.
Caption | ||||
---|---|---|---|---|
| ||||
Click Next. The Ready to complete option is displayed.
Caption | ||||
---|---|---|---|---|
| ||||
Receive side scaling (RSS) is a mechanism that enables spreading incoming network traffic incoming network traffic across multiple CPUs, thus eliminating a potential processing bottleneck. For SR-IOV configurations, the RSS configuration can must be updated in the ESXi host as follows:
On the ESXi host, execute the following command:
esxcfg-module -u ixgbe
esxcfg-module -
l | grep ixg
vmkload_mod ixgbe max_vfs=2,2
RSS=
max_vfs
is an array of integers representing number of virtual functions to be enabled for required devices and RSS
is an array of integers used to enable RSS for the required devices.4,4
esxcfg-module -s 'max_vfs=2,2, RSS=4,4' ixgbe
Once the VMware instance is created, you must install the SBC application.
Perform the following steps:
Click Edit. The Edit Settings window is displayed.
Select CD/DVD Drive 1.
Caption | ||||
---|---|---|---|---|
| ||||
Include Page | ||||
---|---|---|---|---|
|
The Datastore browser window is displayed. Browse the ISO image file.
Caption | ||||
---|---|---|---|---|
| ||||
Click Select. The following window is displayed.
Caption | ||||
---|---|---|---|---|
| ||||
Click Power on to power on the VM.
Caption | ||||
---|---|---|---|---|
| ||||
The Sonus SBC Installer window is displayed. Press Enter to boot.
Caption | ||||
---|---|---|---|---|
| ||||
Once the installation completes, you are prompted to enter the login credentials.
Caption | ||||
---|---|---|---|---|
| ||||
Log on to CLI as linuxadmin
. Provide the following IP addresses:
Primary Management IPv4 Address
Primary Management Network Mask
Primary Management Gateway IP Address, you are prompted to use IPv6 address.
n