Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Add_workflow_for_techpubs
AUTH1UserResourceIdentifier{userKey=8a00a0c86e9b2550016ec54396b5000a, userName='null'}
JIRAIDAUTHSBX-107671
REV5UserResourceIdentifier{userKey=8a00a02355cd1c2f0155cd26cb8305e9, userName='null'}
REV6UserResourceIdentifier{userKey=8a00a02355cd1c2f0155cd26cb8305e9, userName='null'}
REV3UserResourceIdentifier{userKey=8a00a02355cd1c2f0155cd26cbbf066d, userName='null'}
REV1UserResourceIdentifier{userKey=8a00a02355cd1c2f0155cd26cbbf066d, userName='null'}

 


Panel

In this section:

Table of Contents
maxLevel4



Info
iconfalse

Related articles:

Identify and download the correct firmware file for your platform type. The upgrade fails if the selected firmware upgrade file does not match the platform type. The following table identifies the correct firmware files for an upgrade:

Platform TypeFirmware file
SBC 5000 Series
(5100, 5110, 5200, 5210)

Upgrade from 2.x to 3.x version:

  • bmc5X00_v3.xx.00-R000.rom
  • bmc5X00_v3.xx.00-R000.rom.md5sum

Upgrade from 3.x to 3.y version:

  • firmware-5XX0-V03.yy.00-R000.img
  • firmware-5XX0-V03.yy.00-R000.img.md5
SBC 5400

Upgrade from any version to latest version:

Upgrade Paths

  • firmware-5400-V03.xx.00-R000.img
  • firmware-5400-V03.xx.00-R000.img.md5
SBC 7000 Series (Refer to Upgrading the BMC and BIOS Firmware for the procedure.)

Upgrade from any version to latest version:

  • firmware-7x00-V03.xx.00-R000.img
  • firmware-7x00-V03.xx.00-R000.img.md5

Upgrade Paths 

There are two BMC firmware upgrade procedures based on the version from which you are upgrading. Each method requires a different file type as listed in the previous table. The SBC 5000 series supports both paths. The SBC 5400 supports only the upgrade method using the ".img" file.The two BMC Firmware upgrade paths are listed below and identify which file type to use during the upgrade:

  • BMC upgrade from 2.x to 3.x: Use the ".rom" file. 
    For example: To upgrade from BMC 02.16.00 to 03.

    00

    17.00, use "bmc5X00_v3.

    0

    17.0-R0.rom" file.

     
    Info
    titleNote

    The firmware upgrade to 3.x can only be done from version 02.16.00 or later. If the existing BMC version is older than 02.16.00, upgrade it to 02.16.00 using the ".rom" file first and then perform an upgrade to 3.x version using a ".rom" file.


  • BMC upgrade from 3.x to 3.y OR 1.x to 3.y: Use the "Disc Image File.img" file. 
  • For example: To upgrade from BMC 03.00.00 to 03.0417.00, use "firmware-5XX0-V03.0417.00-R000.img" file.
Upgrade BMC Firmware
Info
titleNote

Download the required BMC firmware version prior to continuing. Refer to Downloading Software from the Ribbon Support Portal for details.

Include Page
Screenshots_with_outdated_sw_fw_versions
Screenshots_with_outdated_sw_fw_versions

Upgrading BMC Firmware from Version 2.x (SBC 5000 Series Only)

The following procedure describes how to upgrade the BMC firmware from 2.x version using the ".rom" file.

  1. Log on to the SBC BMC GUI.

    Caption
    0Figure
    1BMC 2.16 Login Screen

    Image Added

     
    The BMC Main screen is displayed. 

    Caption
    0Figure
    1BMC 2.16 Main Screen

     Image Added


  2. Click Remote Control. The Remote Control window is displayed.

    Caption
    0Figure
    1BMC 2.16 Remote Control Screen
     Image Added



  3. Click Power Control in the Options panel. The Power Control and Status window is displayed. 

    Caption
    0Figure
    1BMC 2.16 Power Control Screen

    Image Added 



  4. Choose Power Off Server - Orderly Shutdown option. 

    Info

    The BMC server must be shut down prior to performing a firmware upgrade.


    Caption
    0Figure
    1BMC 2.16 BMC Orderly Shutdown

    Image Added

     


  5. Click Perform Action to initiate the shutdown process.

    Caption
    0Figure
    1BMC 2.16 BMC Shutdown

    Image Added



  6. Click the Maintenance tab. The Maintenance window is displayed.

    Caption
    0Figure
    1BMC 2.16 Maintenance Window

    Image Added



  7. Click Enter Update ModeConfirm that you want to enter update mode when prompted.

    Caption
    0Figure
    1BMC 2.16 Maintenance Window Confirmation Message

    Image Added



  8. Click OK to proceed. The BMC is now in Upgrade Mode.

    Caption
    0Figure
    1BMC 2.16 Firmware Update window

    Image Added



  9. Browse and select the firmware file to upload. The firmware file to upgrade from 2.x version should be a .rom file. For example: bmc5X00_v3.17.0-R0.rom file.

  10. Click Upload Firmware. The BMC validates the selected file.

    Info
    titleNote

    The BMC fails to upgrade if:

    • the selected version is same as the existing version.
    • the selected version is older than the existing version.
    • the selected firmware image is incorrect for the platform type. For example, selecting an SBC 5400 firmware file for an upgrade on the SBC 5000 Series platform.


    Once the verification is complete, a message is displayed stating the result of the verification.

    Caption
    0Figure
    1BMC 2.16 Firmware Validation

    Image Added



  11. Click OK to proceed. The existing and the new BMC versions are displayed for validation.

    Caption
    0Figure
    1BMC 2.16 Firmware Comparison

    Image Added



  12. Click Start Upgrade to initiate the upgrade process. Confirm that you want to upgrade when prompted.

    Caption
    0Figure
    1BMC 2.16 Upgrade Confirmation message

    Image Added

     


    Warning
    titleWarning

    Once the upgrade process starts, do not close the screen.

    • If the window is closed or connectivity is lost before the upgrade starts, re-login to BMC GUI and reboot BMC. The BMC takes approximately 10 minutes to boot. Once the BMC boots up, re-login to BMC GUI and restart the upgrade process from
the BMC web GUI.
    • step 1.
    • If the window is closed or the connectivity is lost during the upgrade process, wait for 20 minutes for the upgrade process to complete and try to access the BMC again. If you fail to gain access, contact Technical Support for assistance.


  1. Click OK to proceed. The BMC starts the firmware upgrade process.

    Caption
    0Figure
    1BMC 2.16 Upgrade Process

    Image Added


    Once the upgrade process is complete, the BMC reboots and a message appears requesting you to open a new browser window to access the BMC GUI.

    Caption
    0Figure
    1BMC 2.16 Upgrade Process Complete

    Image Added


  2. Exit the browser. 
  3. Clear the browser cache.
  4. Open a new browsing window to access the BMC GUI again.
  5. Access the same BMC IP address to reach the BMC login window. In the new BMC version (3.X), the login window includes additional browser settings.

    Caption
    0Figure
    1BMC 3.X Login Window

    Image Added



  6. Log on to the SBC BMC GUI.

Anchor
Upgrade BMC Firmware from 3.x Version for SBC 5400 and SBC 5000/7000 Series
Upgrade BMC Firmware from 3.x Version for SBC 5400 and SBC 5000/7000 Series
Upgrading BMC Firmware from Version 3.x or 1.x

The following procedure describes how to upgrade the BMC firmware from a 3.x version to a 3.y version (for example, from version 03.10.00 to version 03.17.00) or from 1.x to a 3.x version using the ".img" file.

  1. Log on to the SBC BMC GUI.Log on to the SBC BMC using the following credentials:
    Username: root
    Password: superuser

    Caption
    0Figure
    1BMC Login Screen

    Image RemovedImage Added

    The BMC main screen is displayed.

    Caption
    0Figure
    1SBC BMC Main Screen
    Image Removed

    Image Added


  2. Click Click Firmware Update.

    Caption
    0Figure
    1BMC Firmware Update option
    Image Removed

    Image Added


    The Firmware Update screen is displayed.

    Caption
    0Figure
    1BMC Firware Update screen
    Image Removed

    Image Added


  3. Click Click Browse, and from the Open dialog browse to to and select select a firmware-5XX0-V<release>.img firmware  firmware image. Refer to the Warning table at the start of this page to make sure you have chosen the correct type of file for an upgrade. To  To determine the exact firmware version, see refer to the release notes in SBC Release Information for guidance.
    The chosen file displays next to the Browse button.

    Caption
    0Figure
    1Selected Firmware file

    Image Removed


     

  4. Click Upload.

    Info
    titleNote

    Click Upload.

    Note

    The firmware image is approximately 26MB file 17MB for the SBC 5000 Series and 24MB for the SBC 5400 and takes few minutes to upload based on the network.


    Info
    titleNote

    The BMC fails to upgrade if:

    • the selected version is same as the existing version.
    • the selected version is older than the existing version.
    • the selected firmware image is incorrect for the platform type. For example, selecting an SBC 5400 firmware file for an upgrade on the SBC 5000 Series platform.

     The selected file is verified and the uploading process starts. Caption0Figure1Uploading Firmware file

    Image Removed


  5. Once the file verification is complete, BMC seeks your permission to proceed further with the upgrade. Click Confirm to proceed. confirm that you want to continue with the upgraded by clicking Confirm in the Firmware Update window.

    note
    Note
    titleCaution

    This is a service-affecting procedure and will power off the host side of the SBC.

    Include Page
    _Host Shutdown Failure During BMC Upgrade
    _Host Shutdown Failure During BMC Upgrade

    Once the
    Caption
    0Figure
    1Firmware verification and confirmation window

    Image Removed

    Once upload starts, the actions performed are displayed in the same window along with the estimated time left to complete the process.

    Warning
    titleWarning

    Once the upgrade process starts, do not close the screen.

    • If the window is closed or connectivity is lost before the upgrade starts, log back into BMC GUI and restart the upgrade process from step 1.
    • If the window is closed or the connectivity is lost during the upgrade process, wait for 20 minutes for the upgrade process to complete and try to access the BMC again. If you fail to gain access, contact Technical Support for assistance.

    Once the update process is complete, a completion message displays

    Caption
    0Figure
    1Firmware upload status

    Image Removed

    Once the upload process is complete, a message is displayed stating the same.

    Caption
    0Figure
    1Firmware
    Upload
    Update Complete message
    Image Removed

    Image Added


  6. Click Click OK to  to complete the process.The BMC automatically restarts at the this point.

  7. Close the existing browser window.

  8. Clear the browser cache and log on to the BMC GUI again. The updated BMC version is displayed on the BMC main screen.

note
  1. .

  2. Log onto the BMC GUI.

     The SBC BMC prompts you to change the password after a successful upgrade only if it is a default password.

    Info
    iconfalse
    titleNote

    This change is applicable only when the BMC is upgraded to version 03.16.00 and later versions. 


    Caption
    0Figure
    1Change Default Password Window

    Image Added


  3. Click OK to proceed. The User Management window is displayed.

    Info
    iconfalse
    titleNote

    You have an option to cancel the action. If canceled, the password remains the same as the default password and you are allowed to continue to work on BMC. However, the warning message is displayed again on your next login to BMC. This reminder continues until the password is changed. For information on how to successfully change the SBC BMC password, refer to Changing the BMC Password


  4. Verify the upgraded version in the BMC main screen.

Continue to Upgrading SBC Application.
Info
titleNote
For HA configuration, refer to Upgrade Flows for guidance

For HA configuration, refer to Upgrade Flows for guidance.

Noprint
Panel
borderColorgreen
bgColortransparent
borderWidth2


Pagebreak