Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Add_workflow_for_techpubs
AUTH1UserResourceIdentifier{userKey=8a00a02355cd1c2f0155cd26cb8305e9, userName='null'}
JIRAIDAUTHSYM-23292
REV5UserResourceIdentifier{userKey=8a00a02355cd1c2f0155cd26cb8305e9, userName='null'}
REV6UserResourceIdentifier{userKey=8a00a02355cd1c2f0155cd26cb8305e9, userName='null'}
JIRAIDAPPR2SYM-23294
REV3UserResourceIdentifier{userKey=8a00a02355cd1c2f0155cd26ce320b29, userName='null'}
JIRAIDAPPRSYM-23293
REV1UserResourceIdentifier{userKey=8a00a02355cd1c2f0155cd26cc7d083d, userName='null'}

CSS Stylesheet
img.confluence-embedded-image { display: inline-block !important; }

The

Spacevars
0product
 allows you to configure the Identification information, Physical Data Layer, and Networking Layer for the Ethernet ports. If you want to change the IP Address, you must configure the associated Logical Interface or use the Modify Ethernet IP task found under the Tasks tab.

Note

Applying configuration to Ethernet ports can cause brief disruption to IP connectivity.

Info

The third Ethernet port on the

Spacevars
0product
is available only if running v2 hardware and Release 6.0.0 or later. For hardware details, see Sonus Ribbon SBC 1000 Hardware Specifications.


To access the Ethernet Ports:

  1. In the WebUI, click the Settings tab.
  2. In the left navigation pane, go to Node Interfaces > Ports.

    Panel
    borderStylenone
    Caption
    0Figure
    1Ethernet Ports - SBC 1000

    Image RemovedImage Added

Configuring the Ethernet Ports on the 
Spacevars
0product

Click the expand ( Image Modified) icon next to the port you wish to configure.

 

Panel
borderStylenone

Caption
0Figure
1Ethernet Port - PrimaryRedundancy Dropdown List

Image Added

 

 

With Ethernet Port Redundancy selected:

Image Removed

 

With
Caption
0Figure
1
No Ethernet Port Redundancy selected

Image Added:

Image Removed

Info

The Redundancy option is also available option for Ethernet Port 2 - Secondary. 

Caption
0Figure
1Ethernet Port - SecondaryPrimary (Redundancy Selected)

Image Added

eth_port_change_secondary.pngImage Removed 

 

Identification/Status - Field Definitions

FieldDefinition
Port AliasSpecifies an alternative name for the interface; typically configured by the SNMP-based Network Manager. This parameter is unique among all the interfaces known to the SNMP Network Manager. The value cannot have whitespace characters.
DescriptionDescription for the port or interface. Maximum entry: 64 characters.Admin StateSpecifies the administrative state of the port.

 

Physical/Data Layer - Field Definitions

FieldDescription
Configured Speed

Configures auto-negotiation or a specific speed for the Ethernet port. The default value should be changed only when necessary.

  • Auto: When Auto is selected the port speed is automatically negotiated by the Ethernet port and reported in the Negotiated Speed field.
  • 1000/100/10: The specified port speed 1000 Mbps, 100 Mbps, or 10 Mbps is reported in the Negotiated Speed field.

Configured Duplexity

Specifies auto-negotiation or a specific value for the duplexity of the Ethernet port. Valid entries:  Auto, Full or Half. Default value: Auto. The default value should be changed only when necessary.Gigabit Timing Mode

Defines the interface timing mode for the Ethernet port. Valid entries:

Auto: The interface timing mode is negotiated during auto-negotiation (Preferred). Default entry

Master: The SBC drives the interface timing

Slave: The peer drives the interface timing

WARNING!

This field should strictly be left as Auto unless interoperability problems are seen with a specific switch. For example, HP 1920 is a potential example of a switch in which Sonus has seen interoperability problems.

 

Networking - Field Definitions

Determines the Access Control List (ACL) to be used when filtering forwarded (i.e. routed) packets received on this port. For more information about Access Control Lists, see Managing Access Control Lists.
FieldDescription
ACL InDetermines the Access Control List (ACL) to be used on this port when filtering incoming packets. For more information about Access Control Lists, see Managing Access Control Lists.
ACL Forward
Frame Type

Specifies the type of Ethernet frames that can be received on this port.

  • All: When selected, both untagged and tagged Ethernet frames are accepted on this port.
  • Untagged: When selected, only untagged frames are accepted on this port.
  • Tagged: When selected, only tagged frames are accepted on this port, and no default VLAN will be configured.

Note: The ASM 1 Ethernet port is limited to Untagged mode only.

Default Untagged VLAN

Specifies the default VLAN to which untagged frames will be assigned when they are received on this port. Visible only when Untagged or All is selected from the Frame Type list box. For more information about VLANs, see Creating and Modifying VLANs.

Note: By default, each Ethernet port will be assigned to their own port specific system created VLAN (e.g. Ethernet 1 VLAN). When the port specific VLAN is selected, IP layer communication takes place with its default Logical Interface (e.g. Ethernet 1 IP).

Note: This option cannot be configured if the port is configured for failover redundancy.

Tagged VLANs

Specifies the tagged VLAN(s) of which this Ethernet port is a member. Only user created VLANs can be selected. Visible only when Tagged or All is selected from the Frame Type list box. Since the ASM 1 Ethernet port is limited to Untagged mode only, the Tagged VLAN selection is not be present for this port.

 

Note: This option cannot be configured if the port is configured for failover redundancy.

Ethernet Port Redundancy - Field Definitions

FieldValue/RangeDescription
Redundancy

(Previously called MSTP State.)

None (0)
MSTP (1)

Failover (2)

Describes redundancy state.
Redundant PortNone
Ethernet 1
Ethernet 2
Ethernet 3
Ethernet 4*
List will reflect platform type and not offering the port currently being configured as redundant port.
Redundancy RolePrimary (0)
Secondary (1)
Read-only field.
Redundancy StateOnline (0)
Backup (1)
Read-only field that indicates which Ethernet port is active.

 

 

*Note: Ethernet 3 is not an available option on older hardware.

Logical Interface Changes

When modifying the primary port for redundancy, the 

Spacevars
0product2
 will automatically change certain Logical Interface settings for the secondary. Refer to the note on Managing Logical Interfaces for details. 

Pagebreak