Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Updated description as per SBX-60663.

Type: MAJOR 

Description

This alarm is generated when a indicates that the specified Trunk Group's registrations due to implicit or child registrations reaches maximum registration limit set by CAC.configured maximum registration limit is reached due to one of the following conditions:

  • Number of registrations received on the ingress leg exceeds the configured limit
  • Number of implicit/child registrations received on the ingress leg exceeds the configured limit

Repetition

None

Event Codes

sonusAlarmNodeID
sonusAlarmLevel
sonusAlarmSequenceId
sonusAlarmTime
sonusAlarmDescription
sonusSipTgName

Instance Fields

sonusSipTgName

Action

None

Impact

None

Clearing

Manual

Infonote
titleNote

The maximum number of registration limit can be configured by user.