Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: changed "Oracle" to "PostgreSQL" based on SBX-89937

Add_workflow_for_techpubs
AUTH2bscoggins
AUTH1barnou
JIRAIDAUTHSBX-57592
REV5bscoggins
REV6bscoggins
REV3sbardhan
REV1rchoudhury

Type: CRITICAL

Description

This alarm is generated when the Oracle PostgreSQL (configuration) and CDB (policy) databases are out of sync on the active SBC. Manual action is required to clear this. See the Action field below for guidance.

Repetition

None

Event Codes

sonusSbxSystemName
sonusSbxServerName
sonusSbxRedundencyRole

Instance Fields

None

Action

Reload the databases from a known good backup.

Impact

The configuration and policy databases are out of sync on the active SBC. The system may not operate as expected.

Clearing

Automatic, sonusDatabaseConfigPolicyDataInSyncNotification