width | 24px |
---|
...
Panel |
---|
...
borderColor | green |
---|---|
bgColor | transparent |
borderWidth | 2 |
...
Back to Installing SBC 5400 Hardware
Back to SBC 5400 Hardware Installation Overview
In this section:
|
...
|
Sonus provides the following Customer Replaceable Units (CRUs) which are, as the name implies, replaceable by the customer on site.
Caption | ||||
---|---|---|---|---|
| ||||
|
Equipment Requirement | Description |
---|---|
Fan Assembly | Three cooling fan assemblies located behind the front |
...
bezel. | |
Solid State Drive | Solid State Disk (SSD) storage accessible from rear of the chassis. |
...
Air Filter | Located within the front |
...
bezel assembly for filtering the air drawn into the chassis by the cooling fans. | |
SFP/SFP+ | Single or Multi mode fiber transceivers (LC type connector) or copper SFP/SFP+ used for Ethernet connections to Media ports and HA ports. |
...
Power Supply | Up to two DC or AC power supplies accessible from rear of chassis. |
Bezel | Secures replaceable air filter to front of the chassis and contains the LED status indicators. |
DSP2x | DSP2x Signal Processing Cards (plug-in module with a high capacity DSP card). |
...
Spacevars | ||
---|---|---|
|
...
The Signal Processing Server (SPS)
...
for the
Spacevars | ||
---|---|---|
|
...
provides increased signal processing capabilities by incorporating the latest DSP technology.
The DSP2x cards contain the actual DSP processing resources. The
Spacevars | ||
---|---|---|
|
...
includes four DSP slots
...
. The
...
DSP modules are hot swappable and installable/replaceable in the field.
The DSP2x module includes a Field-Programmable Gate Array (FPGA) that may occasionally require reprogramming. The reprogramming is fully autonomous and occurs during system reboot process. The only noticeable effect to the system is a slight increase to the duration of the system reboot. For each DSP2x installed, expect an additional 1-2 minutes added to the length of a normal reboot process.
Log messages pertaining to FPGA reprogramming are stored in the following files:
sbx_start.log_(timestamp)
file is located in /var/log/sonus/sbx/openclovis
directory. This file contains all logs related to system startup as well as a log of other scripts that call this FPGA reprogramming utility./var/log/messages
file....
The ESD Susceptibility symbol
...
warns of the presence of Sonus devices susceptible to electrostatic discharge. Do not handle equipment without wearing a properly grounded ESD wrist strap.
Pagebreak |
---|