Include PageIPMI_Security_VulnerabilityIPMI_Security_VulnerabilitySonus ships the 

Spacevars
0model5
pre-configured with the default IP address, “169.254.77.1” to facilitate out of the box access to the BMC web interface. Configure your PC/Laptop IP address to be on this network so that it can communicate with with the 
Spacevars
0model5
platform. To access the BMC web application, connect the Field Service Port to the PC configured with the pre-configured IP address and type the IP address in a web browser.

To configure BMC for remote access:

...

using an Ethernet crossover cable, connect the Field Service Port (FSP

...

Spacevars
0model5

...

) to a PC Ethernet port configured for 100 Mbps (Full Duplex) with an IP Address in the same subnet (for example, 169.254.77.2 /24) and connect to the pre-configured IP address in a web browser.

To configure the BMC for remote access:

  1. Enter "

  2. .
    Caption
    0Figure
    1SBC 5400 - connecting PC to FSP

    Image Removed

  3. Verify that both the LEDs at the FSP are lit. If only the left LED is lit, your PC/laptop network adapter link speed may be set to 10Mbps. Check the PC/laptop Device Manager, and if necessary set your PC/laptop link speed to 100 Mbps/Full Duplex.
  4. If your PC/laptop uses DHCP and Automatic Private IP Address setting (default setting), the PC/laptop is assigned an IP address in the same subnet as the initial BMC IP; therefore proceed to Step 9. If your PC/laptop does not use DHCP, proceed to the Step 4 to configure a static IP.
  5. In Windows 7 operating system, Open Control Panel > Network and Sharing Center. The Network and Sharing Center window is displayed.

    Caption
    0Figure
    1Network and Sharing Window

    Image Removed

  6. Click Local Area Connection link.The Local Area Connection Status screen is displayed.

    Caption
    0Figure
    1LAN Connection Status

    Image Removed

  7. Click Properties. The LAN Properties screen is displayed.

    Caption
    0Figure
    1LAN Properties

    Image Removed

  8. Select Internet Protocol Version 4 (TCP/IPv4) and click Properties. The Internet Protocol Version 4 (TCP/IPv4) Properties window is displayed.

    Caption
    0Figure
    1TCP-IPv4 Properties Window

    Image Removed

  9. Select Use the following IP addresses and add the IP address, Subnet mask, and Default gateway values. Click OK.

    Caption
    0Figure
    1TCP-IP Properties Window

    Image Removed

  10. AnchorStep9Step9Type the pre-configured IP address “169.254.77.1” in a web browser (Firefox is the recommended browser. If using Internet Explorer, you must manually add “https://169.254.77.1” as a trusted site), and 1" into a supported browser (Firefox or IE) to connect to the BMC web interface.GUI.

    note
    Info
    iconfalse
    titleNote

    The SBC 5400 is delivered with sample self-signed X.509 certificates. Please be aware that even though these sample certificates will allow you to use HTTPS to access the SBC 5400 from BMC and EMA interfaces, using this protocol with the sample certificates is not a truly secure access method. If your organization requires a more secure access, see Generating PKI Certificates. 

  11. Login Log on to the 

    Spacevars
    0model5
    BMC GUI.

    At the prompt, enter:

    Code Blocklanguage

    none

    Username: root
    Password: superuser 

    The

    Spacevars
    0model5
    BMC main screen is displayed.

     

  12. Click Configuration > Network tab.

    Caption
    0Figure
    1BMC Configuration Path


    The Network Settings screen is displayed.

    Caption
    0Figure
    1BMC Network Settings Screen

  13. Configure the IPv4 Address, Subnet Mask and Default Gateway network settings. Else, select Use DHCP to obtain the IPv4 configuration details automatically.
  14. Select the Select Enable JViewer, and/or Enable SSH and Enable IPMI options under Security  options under the “Security” settings depending upon your security requirements.

    Click Save.

    Caption
    0Figure
    1Configuring BMC Network

    Image Removed

    It is recommended to leave the Enable IPMI option disabled.

    Note

    Enable IPMI is a service impacting operation. This reboots both the BMC and the host server. The changes to any of the three security items does not occur until the Save button is clicked.

    Include Page
    IPMI_Security_Vulnerability
    IPMI_Security_Vulnerability

  15. Click Save.

    Caption
    0Figure
    1Configuring BMC Network

    Image Added

    Caption
    0Figure
    1Rebooting BMC for Enabling IPMI


    Click Ok to reboot the BMC.

  16. Once you click Save, the following warning message appears:

    Caption
    0Figure
    1BMC Network Configuration Warning Message

  17. Click OK to proceed. A pop up window appears stating that the security configuration is successfully completed.

    Caption
    0Figure
    1Successful Configuration Message

  18. Click OK to complete the process.
  19. Disconnect the PC/Laptop from the FSP.
  20. Connect the FSP of 

    Spacevars
    0model5
    to the Ethernet router on LAN segment using a CAT5 Ethernet cable to access the BMC over the networkallow remote access of the BMC.

    Caption
    0Figure
    1Field Service Port

  21. Connect a PC/Laptop to the IP network that can access the BMC IP address.

  22. Continue to configure network management interfaces.

note
Info
iconfalse
titleNote

Once the real BMC address is configured, you cannot access the pre-configured BMC address. Clear the browser cache (browser-specific) and open a new browser session to reflect the changes. 

 