Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Add_workflow_for_techpubs
AUTH1ghoppe
JIRAIDAUTHSYM-22659
REV5ghoppe
REV6ghoppe
REV3aelshama
REV1
 
mwoisin

 

Div
classexcerptdiv
Excerpt

This section describes the dimensional, environmental, power, and network specifications and requirements for the Sonus SBC 1000

Spacevars
0series
System.

 

Include Page
Not_for_SWe
Not_for_SWe
 

Dimensions and Weight

Equipment

Height mm/in.

Width mm/in.

Depth mm/in.

Weight lb./kg

Chassis with no interface cards or expansion modules

42.00 / 1.65

441.60 / 17.38

299.00 / 11.77

8.50 / 3.85

Maximum supported configuration

(1RU) - 44 mm / 1.75 in

444 mm / 17.5 in.

305 mm / 12 in.

5.67 kgs / 12.5 lbs

Environmental Ranges (Operation and Storage)

Environmental Parameter

Specification

Operating Environmental Conditions

Temperature: 5º to 40º Celsius Humidity: 5% to 85% RH non-condensing Altitude: 60 meters below sea level to 1800 meters above sea level

Storage Environmental Condition

Temperature: -40º to 70º Celsius

Cooling System

Internal forced convection

Power Supply

Wiki Markup
{multi-excerpt-include:pageTitle=Sonus SBC 1000-2000 System Power Supplies|name=1000specs|nopanel=true}
For more information about the Sonus SBC 1000 the 
Spacevars
0series
power supply units, see Sonus Ribbon SBC 1000-2000 System Power Supplies.

Ethernet Port Pinouts

The 10/100/1000 Base-T port pinouts are as follows:

...

Additional Resources

Children Display

Pagebreak