Object ID1.3.6.1.4.1.2879.2.10.1.1.1.0.62

Description

This alarm is raised when the TCP connection to a particular monitoring server cannot be is not established after three failed attempts (IPv4).

Repetition

Yes

Event Codes

  • sonusAlarmNodeID
  • sonusAlarmLevel
  • sonusAlarmSequenceId
  • sonusAlarmTime
  • sonusAlarmDescriptin
  • sonusMonIpAddress
  • sonusMonPortNum

Instance Fields

  • sonusMonIpAddress
  • sonusMonPortNum

Action

Reestablish Re-establish the TCP connection.

Info
titleNote

Manually You must manually disable or enablethe enable the monitoring profile state after taking correction corrective actions.

Impact

The SBC cannot stream SIP PDUs to the monitoring server because since the TCP connection is not established.

Clearing