Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

 

This window displays SBC Daughter Board (DB) module status detailsUse the Daughter Board Status window to view the status of SBC Daughter Board modules in SBC 5xxx and SBC 7000 systems.

Include Page
Not_for_SWe
Not_for_SWe

On the

Spacevars
0product
 main screen, go to Monitoring > System > Category: Hardware Status >Daughter Board Status. Status or
All > System > Daughter Board Status

The Daughter Board Status window is displayedopens.

Caption
0Figure
1Daughter Board Status
Image Added 

Image Removed 

The following fields are output is displayed:

 
Caption
0Table
1system daughterBoardStatus Parameters
Daughter Board Status Parameters

Parameter

Description

Server NameServer name.
Slot Specifies the slot associated with the

...

board.
Daughter Board

...

ID

Daughter board identifier.

Spacevars
0series
:

  • SPS100 – SBC 5x00 SPS100 module
  • DB0 – SBC 5x00 SPS100DB 0 module
  • DB1 – SBC 5x00 SPS100DB 1 module
  • DSP20 – SBC 5x10 DSP20 module
  • DSP25 – SBC 5x10 DSP25 module

Spacevars
0series2
:

  • FRU_DSP1

...

  •  – SBC 7000 DSP-LC slot 1
  • FRU_DSP2 SBC 7000 DSP-LC slot 2

  • FRU_DSP3 SBC 7000 DSP-LC slot 3

  • FRU_DSP4 – SBC 7000 DSP-LC slot 4

PresentIndicates if the module is present (True or

...

False).
Product NameIdentifies manufacturer module name (if present).
Serial Num

Identifies the serial number of the module (if present).

Note
The maintenance fields Image Load Failure Count and Fpga Version  do not apply to SPS100 cards.
Operational Status Operational state of daughter board.

    ...

    • Disabled – Card is disabled.

    ...

    • Dryup – Card is enabled but in the process of drying up. Once completed, card will be set to ‘disabled’.

    ...

    • Enabled – Card is enabled.

    ...

    • Failed – If a DSP2x or DSP-LC module fails to boot over three consecutive tries (typically due to a hardware failure), it is taken out of service and marked as state “failed”. The rest of the system continues to boot normally, including any other DSP modules. The module failure is logged/alarmed with trap “sonusConnexIpSystemCESlotFailedNotification”. The slot remains in the failed state until the module is disabled and re-enabled once a replacement card is installed.

    ...

    • Loading – Card is enabled but in the process of booting. Resources are not yet available. Once completed, card will be set to ‘enabled’.

    ...

    • Locked – Slot capacity is locked out due to mismatch (with

    ...

    • “Preserve Redundancy” configured).

    ...

    NOTE: For 5x00 systems, only the

    ...

    Enabled state displays in the results.
    Image Load Failure Count

    ...

    Number of module boot failures since the last successful module boot, for use during diagnostic testing of a potentially failed module.

    NOTE: This maintenance field does not apply to SPS100 cards.

    Fpga

    ...

    Version 

     A card’s programmed firmware version (using the FPGA build date).

    NOTE: This maintenance field does not apply to SPS100 cards.

    By default only ten entries are displayed in a view. You can choose the number of entries to be displayed under the Show entries drop down box. 

    Pagebreak