The BMC web application allows provisioning of primary and secondary host management interfaces. When the host management interfaces are configured, a direct link from BMC is enabled to EMA for installing and upgrading the
application.
Use the following procedure to configure the primary and secondary host management interfaces:
Login Log on to SBC BMC using the IP address configured in the previous section. At the prompt, enter:
Username: root
Password: superuser
The SBC BMC main screen appears.
Caption |
---|
|
Image Modified |
Click Configuration tab. The Configuration screen displays.
Caption |
---|
0 | Figure |
---|
1 | Configuration Screen |
---|
|
Image Removed |
From Options menu, click > Platform Management Network. The Platform Management Network . A warning message appearsSettings options are displayed. However, if the management addresses are not configured (first time installation), a warning message is displayed stating the same and requesting you to add all the required details.
Caption |
---|
|
|
- Click OK. The Platform Management Network Settings screen displaysdisplayed.
Configure the following network settings for both the Management Interface 0 and 1.
- IPv4 Address or/and IPv6 Address
- Prefix
- Default Gateway
Click Save.
Caption |
---|
0 | Figure |
---|
1 | Platform Management Network Settings |
---|
|
Image Removed |
note |
Image Added |
Click Save.
Info |
---|
|
When upgrading from an application software release prior to SBC 3.1.x, an IPv4-mapped IPv6 address is applied as an unusable placeholder in the IPv6 management address. This mapped address must be removed or set to a valid IPv6 address when updating the management addresses via BMC. |
Info |
---|
|
note |
If you update the Management IP address through BMC and click Save, you must reinstall the SBC application software. If you update the management IP using CLI, EMS or EMA, it is automatically updated in the BMC and re-installation is not required. |
Caption |
---|
|
|
...