This procedure lets you reset the

Spacevars
0product
 (SBC) to factory defaults. You might want to use this procedure in certain recovery scenarios like lost admin password or lost IP address etc.

Warning

Resetting Sonus SBC Edge to factory defaults removes all user-configured data. This including user names, passwords, customized IP addresses, etc..

Note
titleSonus SBC Ribbon 1000/2000 Systems with Built-in ASM

If your ASM is already initialized and Lync SBA is deployed, resetting the SBC to factory defaults does not reset the ASM/SBA configuration settings. If you wish to reset the ASM to factory defaults, then you must Re-initialize the ASM.

...

  1. If the SBC is running, press and hold the Reset button for approximately 20 seconds.
  2. Shutd own Shut down the SBC, press and hold the reset button while the unit is powered on. Hold the reset button until the Alarm Status LED first turns yellow and then goes out.

    Expand
    Click here to see where the Sonus SBC 1000 Reset button is located
    Click here to see where the Sonus SBC 1000 Reset button is located

    Caption
    0Figure
    1SBC 1000 Reset Button

    Image RemovedImage Added

    Expand
    Click here to see where the Sonus SBC 2000 Reset button is located
    Click here to see where the Sonus SBC 2000 Reset button is located

    Caption
    0Figure
    1SBC 2000 Reset Button

    Image RemovedImage Added

  3. Reset the SBC from the user interface.

...

  1. In the WebUI, click the Tasks tab.
  2. In the left navigation pane, go to System > Sonus SBC Edge Factory Default.

    Panel
    borderStylenone

    Caption
    0Figure
    1Factory Default


    Image Removed Image Added

Operation Selections

...