Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Panel

In this section:

Table of Contents
maxLevel2

Warning

Sonus-provided SFP/SFP+ modules must be used to guarantee proper operation of the external ports. Failure to follow this recommendation may cause permanent damage to the system.

Tooltip
tipUse ESD protective device

1 Gb SFP Characteristics

The 

Spacevars
0series2
supports the following Small Form-factor Pluggable (SFP/SFP+) transceivers. The SFPs (SFP/SFP+) are Customer Replaceable Units (CRU).

The following SFP transceivers are compatible with 

Spacevars
0series2
Management ports:

Div
classpdf6pttext

Caption
0Table
11Gb SFP Parts
31Gb SFP Parts
Transceiver TypeProduct CodeSFP TypeManufacturers  Part Number

DescriptionCopper

Wavelength  (nm)Tx Power (dBM)Rx Power (dBM)

Description
Multi-mode fiber

SBC-

SFPCOPPER-1G

SFPMM-1G

 

1G Ethernet
MM

  • AVAGO TECHNOLOGIES AFBR‐5715PZSN1
  • BROADCOM AFBR‐5715PZ‐SN1
  • FINISAR FTLF8519P2BNL‐SS
  • FINISAR  FTLF8519P3BNL‐SS
850-9.5 (Min)-3 (Max)-17 (Min)0 (Max)GIG-E, MULTIMODE, FIBER OPTIC TRANCEIVER MODULE, LC, SMALL FORM

GIGE, 1000 BASE-T SMALL FROM

PLUGGABLE (SFP), 300M
Single-mode fiber

 SBC-SFPSM-1G

 

1G Ethernet  SM
  • AVAGO TECHNOLOGIES AFCT‐5715PZSN1
  • BROADCOM AFCT‐5715PZSN1
  • FINISAR FTLF1318P2BTL‐SS
  • FINISAR FTLF1318P3BTL‐SS
1310-9.5 (Min)-3 (Max)-19 (Min)-3 (Max)

GIG-E, SINGLE MODE, FIBER OPTIC TRANSCEIVER MODULE, LC, SMALL FORM PLUGGABLE (SFP), 10KM 1310NM, DMI

Multi-mode fiber

CopperSBC-

SFPMM

SFPCOPPER-1G

GIG-E, MULTIMODE, FIBER OPTIC TRANCEIVER MODULE, LC, SMALL FORM PLUGGABLE (SFP), 300M

1G Ethernet Copper
  • AVAGO TECHNOLOGIES ABCU-5740RZ-SN1
  • BROADCOM ABCU-5740RZ-SN1
  • FINISAR FCLF8521P2BTL-SS
NANANANANAGIGE, 1000 BASE-T SMALL FROM PLUGGABLE (SFP)

Info
titleNote

These numbers are taken from Vendor Datasheets as well as IEEE 802.3ae for the 1G parts.

 

10 Gb SFP Characteristics

The following SFP+ transceivers are compatible

with SBC 7000 series

with 

Spacevars
0series2
Media and HA ports:

Div
classpdf6pttext

Caption
0Table
110Gb SFP Parts
310Gb SFP Parts
Transceiver TypeProduct CodeSFP TypeManufacturers  Part NumberWavelength  (nm)Tx Power (dBM)Rx Power (dBM)

Description

Single

Multi-mode fiber

SBC-SFPSM-10G10.3GB/S, SINGLE MODE

SBC‐SFPMM‐10G

10G Ethernet
MM

  • AVAGO TECHNOLOGIES AFBR‐709SMZSN1
  • BROADCOM AFBR‐709SMZ‐SN1
  • FINISAR FTLX8571D3BCL‐SS
  • FINISARFTLX8574D3BCL‐SS
850-7.9 (Min)-1 (Max)-11.1 (Min)0.5 (Max)

10.3 GB/S, MULTIMODE, FIBER OPTIC XCVR, LC, SFP

, 10KM 1310NM, DMMulti-mode fiberSBC-SFPMM-10G

, 300M 850NM, DMI GIG-E, SINGLE MODE, FIBER OPTIC TRANSCEIVER MODULE

Single-mode fiber

SBC‐SFPSM‐10G

 

10G Ethernet  SM
  • AVAGO TECHNOLOGIES AFCT‐709SMZSN1
  • AVAGO TECHNOLOGIES AFCT739SMZ‐SN1
  • BROADCOM AFCT‐709SMZSN1
  • BROADCOM AFCT‐739SMZ‐SN1
  • FINISAR FTLX1471D3BCL‐SS
1310-8.2 (Min)0.5 (Max)-12.6 (Min)0.5 (Max)10.3 GB/S, SINGLE MODE

10.3GB/S, MULTIMODE

, FIBER OPTIC XCVR, LC, SFP,

300M 850NM, DMI GIG-E, SINGLE MODE, FIBER OPTIC TRANSCEIVER MODULE

10KM 1310NM, DM

Info
titleNote

These numbers are taken from Vendor Datasheets as well as IEEE 802.3ae for the 10G parts.

 

Parts and Tools Required

Tooltip
tipESD protective device

The following items are needed to install/replace a SFP/SFP+ device:

  • Electrostatic discharge (ESD) strap
  • Replacement SFP/SFP+ transceivers.

Include Page
ESD_wriststrap_7K
ESD_wriststrap_7K

Replacing the SFP/SFP+

To replace the SFP/SFP+:

  1. Attach an Electrostatic Discharge wrist strap by using the ESD grounding point on the back panel of the chassis. Follow the instructions in the section Connecting Electrostatic Discharge Wrist Strap on SBC 7000.
  2. Disconnect the fiber optic and/or Cat 5 cables, as appropriate, from media ports (Media 0-4) and HA ports (HA 0-1).
  3. Disengage the SFP/SFP+ transceiver from

    Spacevars
    0series2
    . The method used to disengage the SFP/SFP+ transceiver will vary according to the manufacturer. For example, hold the wire latch and move it downwards to the horizontal position and pull it outwards.

  4. Insert the Sonus-approved SFP/SFP+ transceiver into the desired socket and ensure that the latch mechanism engages.

  5. Reconnect the fiber optic and/or Cat 5 cables, as appropriate, to media and HA ports.
  6. Verify LEDs above the part are flashing indicating link status and data activity.
  7. Verify port functionality by using the application.

CRU Storage

Tooltip
tipESD protective device

All 

Spacevars
0series2
CRUs are shipped in electrostatic discharge bags and should be handled using appropriate ESD precautions.

The storage environment for these CRUs are:

  • Humidity must be less than 95% (non-condensing).
  • Temperature must be between -40C and +70C.

 

Include Page
ESD_footnote
ESD_footnote

Pagebreak