Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.


Panel

In this section:

Table of Contents
maxLevel2



Excerpt

Use this object to configure H323 Signaling Port for this zone.

Note

Each signaling port within an Address Context must use a unique IP address.

Include Page

...

_Unique_IP_for_SigPort

...

_Unique_IP_for_SigPort

Include Page

...

_IP_IGs_ServedBySeperateProcessors

...

_IP_IGs_ServedBySeperateProcessors

To View H323Sig Port

On the SBC main screen,

...

navigate to:

  • All  > Address Context > Zone > H323Sig Port
  • Configuration > System Provisioning > Category: Base Provisioning > Signaling Ports > H323Sig Port


The H323Sig Port window is displayed.

...

Image Modified

...


You can check the H323Sig Port for each Address Context

...

and Zone or

...

all

...

Address Contexts and Zones

...

. Use the drop-down box to select the desired Address Context and Zone.

To Edit H323Sig Port

To edit any of the H323Sig Ports in the list, click the radio button next to the specific H323Sig Port name.

The Edit

...

Selected H323Sig Port window is displayed

...

.

Figure 2: H323Sig Port Edit Window

Image Removed

Make the required changes and

...

click Save.

Image Added

To Create H323Sig Port

To create a new H323Sig Port,

...

click New H323Sig Port tab on

...

the H323Sig Port List panel.

...

Figure 3: H323Sig Port Fields

Image Removed

 The Create

...

New H323Sig Port window is displayed.

Image Added

...

Image Removed

The following fields are displayed:

Table 1: H 323 Sig Port


H323Sig Port

...

Parameters

Parameter

Description

Index

Specify the index value.

...

IP Interface Group Name

The name of the IP interface group used by this Signaling Port.

...

H225IP Address

The 32-bit IP address used for H225 signaling. Specified in dotted decimal form (for example 128.127.50.224). Default is 0.0.0.0.

...

Port Number

The logical port number of the UDP port to use for this connection. This defines the H.225 well known port. Must be 1-5000, default is 1720.

...

H245IP Address

The 32-bit IP address used for H245 signaling. Specified in dotted decimal form (for example 128.127.50.224). Default is 0.0.0.0. This must equal ipaddress1 in the current implementation.

Mode

The operational state of the H323 signaling service:

...

  • In Service—the signaling port listens for incoming H323 signal link connection requests.

...

  • Out Of Service—the signaling port is not available for incoming H323 signal link connection requests and thus cannot be used to create a new gateway signal links to other H323 gateways.

State

The administrative state of this H323 signaling port:

...

  • Disabled—Not active

...

...

  • Enabled—Active

Action

The method by which active calls using this H323 signaling service are processed when MODE goes to out of service:

...

  • Dryup—all calls are allowed to complete until TIMEOUT expires.

...

  • Force—all calls are dropped immediately.

...

Dry Up Timeout

The time (in minutes) to wait for active calls to finish in order to place the H323 signaling service in out of service MODE. Must be 0-1440, default is 0.

...

DSCP Value

Differentiated Services Code Point value (0-63).

To Delete H323Sig Port

To delete any of the

...

created H323Sig Port, click the radio button next to the

...

specific H323Sig Port.

...

Click Delete

...

 at the end of the highlighted row. A delete confirmation message appears seeking your decision.

...

Click Yes to remove the specific H323Sig Port from the list.