Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

On the main page of each HWMON instance, the following information is provided:

  • For DSC 8000 and SP2000 (3U and 13U):The status (either Initializing or Running) of the instance
  • If the Debug-level logging is enabled or disabled 
  • A list of populated slotsFor DSC 8000 only:
  • The slot where the HWMON instance is running
  • The state of the Critical, Major and Minor Telco Alarm Indicators
  • The Active MCH in the Control chassis
  • The Refresh Time indicating when the data retrieval started in the application

When the HWMON starts up, its status is set to Initializing until all of the components available in the system have been discovered. Once all the components have been discovered, the status is set to Running. It is important to wait for the HWMON instance to transition to Running before depending on the information provided because the information may still be changing.

...

Anchor
View HWMON
View HWMON
To view Hardware Monitor information on DSC 8000

  1. Login to the Web UI.
  2. From the Main Menu, click Hardware Monitor.
  3. Click the required Management Slot Number (2 or 13). 
  4. Click the Slot Number you want to see the Hardware status for. 
  5. Click the required sensor (in this example the Threshold Sensor).


To view Hardware Monitor information on SP2000

  1. Login to the Web UI.
  2. From the Main Menu, click Hardware Monitor.
  3. Click the required Management Slot Number (14 or 24). 
  4. Click the Slot Number you want to see the Hardware status for. 
  5. Click the required sensor (in this example the Threshold Sensor).
  6. Click on Read-Sensor button and confirm.

Anchor
Enable Debug
Enable Debug
To enable Debug Logging

  1. Login to the Web UI.
  2. From the Main Menu, click Hardware Monitor.
  3. Click the required Slot Number.
  4. For the Debug Logging drop-down menu, select ENABLED.

    Info
    titleNote

    The Restore Debug Defaults action restores the Hardware Monitor logging configurations to their default values and clears the associated logging alarms.


  5. Click Continue.

...