Use the SIP JJ9030Interworking Profile window to configure SIP JJ9030 Interworking profiles which contain parameters needed for SIP JJ9030 Interworking. For information on other related profiles for SIP-ISUP and interworking between different SIP variants, refer to Support for SIP-ISUP.
Multiexcerpt include | ||||
---|---|---|---|---|
|
Multiexcerpt include | ||||
---|---|---|---|---|
|
To View SIP JJ9030 Interworking Profiles
On the SBC main screen, navigate to All → Profiles → Signaling → SIP JJ9030Interworking Profile.
The SIP JJ9030Interworking Profile window opens:
To Create a SIP JJ9030 Interworking Profile
To create a new SIP JJ9030 Interworking Profile:
1 Create New SIP JJ9030Interworking Profile WindowClick New SIP JJ9030 Interworking Profile. The Create New SIP JJ9030Interworking Profile window opens.
Caption 0 Figure Use the following table to configure the parameters and then click Save.
Field
The type of SIP parameters and procedures used for this interworking profile.
Length/Range
0 | Table |
---|---|
1 | SIP JJ9030 Interworking Profile Parameters |
The name of this SIP JJ-90.30 Interworking Profile.
NOTE: You can configure a maximum of 32 SIP JJ9030 Interworking Profiles.
Description Add User Equal Phonefor Div Hi Interworking N/A Enable this parameter to add "user=phone" and the "mp" parameter for Diversion History Info Interworking.
- Disabled (default)
- Enabled
BCI Called Party Category N/A The Backwards Call Indicators Called Party Category.
- No Indication
- Ordinary
- Payphone
- Spare
NOTE: This parameter is mandatory when the parameter SIP Flavor is set to SIP-ttc-charging-params.
BCI Charge Indicator N/A The Backwards Call Indicators Charge Indicator.
- Charge
- No Charge
- No Indication
- Spare
NOTE: This parameter is mandatory when the parameter SIP Flavor is set to SIP-ttc-charging-params.
BCI Terminating ISDN Access N/A The Backwards Call Indicators Terminating ISDN Access Indicator.
- Non ISDN
- Isdn
NOTE: This parameter is mandatory when the parameter SIP Flavor is set to
SIP-ttc-charging-params
.
Charge Area Information 5 digits ( 0-9
)The Charge Area Information, consisting of 5 digits (0-9). Name
1-
23 characters The name
of this SIP JJ-90.30 Interworking Profile.
NOTE: You can configure a maximum of 32 SIP JJ9030 Interworking Profiles.
Orig Ioi 1-128 characters The name of the
Originating Inter Operator Identifier. Originating Carrier Code 4 digits ( 0-9
)The Originating Carrier Code, consisting of 4 digits (0-9).
NOTE: This parameter is mandatory when the parameter SIP Flavor is set to JJ9030.
0-9
)The Originating Carrier Code, consisting of 4 digits (0-9).
0-9
)Pnisupr Header Interworking N/A Enable this
flag on SIP JJ9030 leg to support P-N-ISUP-R header interworking in SIP-T to SIP JJ90.30 and SIP JJ90.30 to SIP-T calls.
- Disabled (default)
- Enabled
Set Hi Presentation Restricted N/A Set Presentation Indicator as "restricted" for History Info Interworking.
- Disabled (default)
- Enabled
SIP Flavor N/A The
- Charge
- No Charge
- No Indication
- Spare
type of SIP parameters and procedures used for this interworking profile.
- JJ9030
- SIP-T
- SIP-ttc-charging-params
The Backwards Call Indicators Called Party Category.
- No Indication
- Ordinary
- Payphone
- Spare
NOTE: This parameter is mandatory when the parameter SIP Flavor is set to SIP-ttc-charging-params.
- X-Header
Sipt Originating Carrier Codes For Pnisupr Iwk A list of 4-digit carrier codes,
up to 50 elementsList of supported originating carrier codes on the SIP-T leg for the P-N-ISUP-R header interworking in a SIP-T to SIP JJ9030 call.
Note: You can separate the "sipt Originating Carrier Codes For Pnisupr Iwk" field values using comma. For example: 1234,1235,1236 and so on.
Term Ioi 1-128 characters The name of the Terminating Inter Operator Identifier. Terminating Carrier Code 4 digits ( 0-9
)The Originating Carrier Code, consisting of 4 digits (0-9)
The Backwards Call Indicators Terminating ISDN Access Indicator.
- Non ISDN
- Isdn
.
Transit Pcv N/A When enabled, the SBC transits icid-value, orig-ioi and term-ioi of P-Charging-Vector transparently in JJ90.30 to JJ90.30 calls, using the current trunk group.
- Disabled (default)
- Enabled
Note:
- Enable this parameter only when the parameter SIP Flavor is set to
JJ90.30
. - For example use cases of this parameter, see Use Cases for Transit Pcv and Transit Icid In Invite.
Transit Icid In Invite N/A When enabled, the SBC transits the icid-value in P-Charging-Vector transparently in the INVITE sent on the current trunk for JJ90.30 to JJ90.30 calls.
- Disabled (default)
- Enabled
Note:
- Enable this parameter only when the parameter SIP Flavor is set to
JJ90.30
. - For example use cases of this parameter, see Use Cases for Transit Pcv and Transit Icid In Invite.
To Edit a SIP JJ9030 Interworking Profile
To edit a SIP JJ9030 Interworking Profile:
- Click the radio button adjacent to the name of the SIP JJ9030 Interworking Profile you want to edit. The Edit Selected SIP JJ9030 Interworking Profile window opens.
- Make any required changes to the profile and click Save.
To Copy a SIP JJ9030 Interworking Profile
To copy a SIP JJ9030 Interworking Profile:
- Click the radio button adjacent to the name of the SIP JJ9030 Interworking Profile you want to copy.
- Click Copy SIP JJ9030 Interworking Profile. The Copy Selected SIP JJ9030 Interworking Profile window opens.
- Make any required changes to the profile and click Save.
To Delete a SIP JJ9030 Interworking Profile
To delete a SIP JJ9030 Interworking Profile:
- Click the radio button adjacent to the name of the SIP JJ9030 Interworking Profile you want to delete.
- Click the delete icon (X) at the end of the row.
- Confirm the deletion when prompted.
Info | ||
---|---|---|
| ||
If a SIP JJ9030 Interworking Profile is associated with a SIP trunk group, remove it from the trunk group before deleting it. |